Fig. 10

ductwork

Squeeze

lead wires

connectors

Note:

Fig. 9

Ensure the tap (Fig.2) in vertical position before installation.

    Slide hanger bars onto housing and adjust as needed to fit between 

    framing. Extend the hanger bars to the width of the framing. Holding the 

    ventilator in place.Secure hanger bars to framing using one screw on each 

    end of hanger bar (refer to the right diagram).

    Screw hanger bar to housing with screw A.

Distance A

14 in to 23 1/2 in (356mm-597mm)

19 11/16 in to 23 1/2 in (500mm-597mm)

Hanger Bar A

Hanger bar (short)

Hanger bar (long)

The choice of Hanger Bar A

Hanger bar A

ASSEMBLY INSTRUCTIONS

e. Wall installation with hanger bars only

Run 120V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the 

wiring plate. Refer to the wiring diagram, and connect the wires as shown.

CONNECT ELECTRICAL WIRING

FAN

WIRE

 PANEL

UNIT

BLACK (BLK)

SWITCH BOX

FAN

POWER SUPPLY

120V AC

GROUND (GRD)

WHITE(WHT)

FAN 

RECEPTACLE

2. Install ductwork and  junction box

Remove junction box cover and secure conduit or stress relief to

junction box knock-out hole.Using connectors 

,

connect house power wires to

ventilating fan wires (refer to wiring diagram) replace the junction box cover.

Squeeze the ductwork to fit the adaptor then slip onto the adapter and

secure it with duct tape (not included) 

,

secure all the ductwork connections

so that they are air tight.

When the product is installed on the wall,the adaptor shall be faced upward.

3

WIRE

 PANEL

UNIT

BLACK(BLK)

SWITCH BOX

FAN

POWER SUPPLY

120V AC

GROUND (GRD)

BROWN(BRN)

WHITE(WHT)

FAN 

RECEPTACLE

FAN

SWITCH B

SWITCH

OX

HUMIDITY SENSOR  /

HUMIDITY SENSOR /

SPEED CONTROLLER

HUMIDITY SENSOR /

SPEED CONTROLLER

HUMIDITY SENSOR /

SPEED CONTROLLER

SWITCH

CONTROLLER RECEPTACLE

For model: PCLP50 , PCLP80 and PCLP100

For humitidy sensor and speed controller function

Содержание PCLP50

Страница 1: ...vice disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards d Sufficient air is needed for proper combustion and exhausting of gases through the flue chi...

Страница 2: ...ing using one screw on each end of hanger bar refer to the right diagram Screw hanger bar to housing with screw A Distance A 14 in to 23 1 2 in 356mm 597mm 19 11 16 in to 23 1 2 in 500mm 597mm Hanger Bar A Hanger bar short Hanger bar A Hanger bar long The choice of Hanger Bar A Screw A Screw B Screw B d Mount to I joist Slide one hanger bar long into channel B on the housing and adjust as needed t...

Страница 3: ...nd connect the wires as shown CONNECT ELECTRICAL WIRING FAN WIRE PANEL UNIT BLACK BLK SWITCH BOX FAN POWER SUPPLY 120V AC GROUND GRD WHITE WHT FAN RECEPTACLE 2 Install ductwork and junction box Remove junction box cover and secure conduit or stress relief to junction box knock out hole Using connectors connect house power wires to ventilating fan wires refer to wiring diagram replace the junction ...

Страница 4: ...maintenance and service or any parts that have been subject to misuse negligence accident improper maintenance or repair faulty installation or installation contrary to recommended installation instructions S P s obligation to repair or replace at S P s option shall be the purchaser s sole and exclusive remedy under this warranty No labor or materials are covered by this warranty S P shall not be ...