WARNING

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

CLEANING & MAINTENANCE

OPERATION

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off

    power unit.

4. Please read specification label on product for further information and requirements.

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit

with the dust brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noi-

ses, replace the motor with the exact service motor. The impeller should also be replaced.

Use an on/off switch to operate this fan. See “Connect Wiring” for details.

PLAN THE INSTALLATION

1. Do not use in a cooking area.

2. Two ways to connect ductwork to a factory-shipped unit.

1

VENTILATION FAN

MODEL: PCLP50      PCLP80         

               PCLP100    

a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent 

power from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.

c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and 

standards, including fire-rated construction codes and standards.

d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning 

equipment to prevent backdrafting.Follow the heating equipment manufacturer’s guideline and safety standards such as 

those published by the National Fire Protection Association (NFPA),and the American Society for Heating, Refrigeration 

and Air Conditioning Engineers (ASHRAE), and the local code authorities.

e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

f). Ducted fans must always be vented to the outdoors.

g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit (ceiling installation only).

h). This unit must be grounded.

i). Not for Use in Kitchens.

j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within 

walls or ceilings or into attics,crawl spaces, or garages.

k). WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control 

Device.

l). The fan must not be installed in a ceiling thermally insulated to a value greater R40.

ROOF CAP*

(with built-in

damper)

ROUND

DUCT*

WALL CAP*

(with built-in

damper)

*

 Purchase

separately

POWER

CABLE*

INSULATION*

(Place around and

over Fan Housing.)

Seal gaps

around

Housing.

FAN

HOUSING

ROUND 

ELBOW(S) *

Seal duct

joints with

tape.

Keep duct

runs short

Содержание PCLP50

Страница 1: ...vice disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards d Sufficient air is needed for proper combustion and exhausting of gases through the flue chi...

Страница 2: ...ing using one screw on each end of hanger bar refer to the right diagram Screw hanger bar to housing with screw A Distance A 14 in to 23 1 2 in 356mm 597mm 19 11 16 in to 23 1 2 in 500mm 597mm Hanger Bar A Hanger bar short Hanger bar A Hanger bar long The choice of Hanger Bar A Screw A Screw B Screw B d Mount to I joist Slide one hanger bar long into channel B on the housing and adjust as needed t...

Страница 3: ...nd connect the wires as shown CONNECT ELECTRICAL WIRING FAN WIRE PANEL UNIT BLACK BLK SWITCH BOX FAN POWER SUPPLY 120V AC GROUND GRD WHITE WHT FAN RECEPTACLE 2 Install ductwork and junction box Remove junction box cover and secure conduit or stress relief to junction box knock out hole Using connectors connect house power wires to ventilating fan wires refer to wiring diagram replace the junction ...

Страница 4: ...maintenance and service or any parts that have been subject to misuse negligence accident improper maintenance or repair faulty installation or installation contrary to recommended installation instructions S P s obligation to repair or replace at S P s option shall be the purchaser s sole and exclusive remedy under this warranty No labor or materials are covered by this warranty S P shall not be ...

Отзывы: