S&P PCD110XM Скачать руководство пользователя страница 2

   Hold the housing so that it is in contact with the bottom of the joist. Attach 

   the housing with four (4) screws to the joist through the holes in each 

   mounting flange.

1. MOUNT HOUSING TO JOIST OR I-JOIST.

HANGER

BAR

2. MOUNT WITH HANGER BARS

    2a. Sliding hanger bars have been provided, which allow the housing to 

    be positioned accurately anywhere between the framing. The bars span 

    up to 24 in. and can be used on all types of framing: I-joist, standard joist, 

    and truss construction. Slide hanger bars onto housing and adjust as 

    needed to fit between framing.

PLAN THE INSTALLATION

TYPES OF TYPICAL INSTALLATIONS

1. Do not use in a cooking area.

2. Two ways to connect ductwork to a factory-shipped unit.

ASSEMBLY INSTRUCTIONS

1. Housing mounted to I-joists (Start at “ASSEMBLY INSTRUCTIONS 1”)

2. Housing mounted to joists (Start at “ASSEMBLY INSTRUCTIONS 1” )

3. Housing mounted to truss (Start at step “ASSEMBLY INSTRUCTIONS 2”)

2

OPERATION

7 to 9 feet

7 to 9 feet.

Turn on the switch to activate sensor and continuous ventilation 

system. The fan will run continuously at the pre-set low speed. 

When motion is detected, the fan speed increases to high speed.   

When the person exits the area, the fan remains working at high 

speed until the delay time has passed (adjustable 3-30 minutes). 

After the time delay, the fan speed is reduced to the continuous 

ventilation rate.

ROOF CAP*

(with built-in

damper)

ROUND

DUCT*

WALL CAP*

(with built-in

damper)

*

 Purchase

separately

POWER

CABLE*

INSULATION*

(Place around and

over Fan Housing.)

Seal gaps

around

Housing.

FAN

HOUSING

ROUND 

ELBOW(S) *

Seal duct

joints with

tape.

Keep duct

runs short

Содержание PCD110XM

Страница 1: ... a tag to the service panel c Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards d Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufact...

Страница 2: ...ASSEMBLY INSTRUCTIONS 1 Housing mounted to I joists Start at ASSEMBLY INSTRUCTIONS 1 2 Housing mounted to joists Start at ASSEMBLY INSTRUCTIONS 1 3 Housing mounted to truss Start at step ASSEMBLY INSTRUCTIONS 2 2 OPERATION 7 to 9 feet 7 to 9 feet Turn on the switch to activate sensor and continuous ventilation system The fan will run continuously at the pre set low speed When motion is detected th...

Страница 3: ...an housing First insert the sensor plug into the plug base on the power box and then install the grille To attach the grille assembly to the fan housing pinch the grille springs on the sides of the grille assembly and position the grille into the housing with the grille springs in the appropriate slots Push the grille assembly towards the ceiling to secure ASSEMBLY INSTRUCTIONS CONNECT ELECTRICAL ...

Страница 4: ...cement products or parts without charge for any product or part which is found to be defective under normal use This warranty does not cover normal maintenance and service or any parts that have been subject to misuse negligence accident improper maintenance or repair faulty installation or installation contrary to recommended installation instructions S P s obligation to repair or replace at S P ...

Отзывы: