S&P PCD110XM Скачать руководство пользователя страница 1

VENTILATION FAN

WARNING

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

Model:  PCD110XM

CAUTION

CLEANING & MAINTENANCE

OPERATION

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting 

brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the 

motor with the exact service motor. The impeller should also be replaced.

-

+

-

+

1 2 3

1 2 3

Toggle 

switch

Power box

Low airflow 

knob

Timer delay

 knob

90

110

120

140

1 2 3

1 2 3

1 2 3

1 2 3

6"

Switch 

position

Duct 

diameter

(inches)

Airflow

(CFM)

6"

6"

6"

90

110

120

140

1 2 3

1 2 3

1 2 3

1 2 3

6"

Switch 

position

Duct 

diameter

(inches)

Airflow

(CFM)

6"

6"

6"

is the position of switch

Factory setting: 110CFM (                    ) 

HVI Certified performance based on HVI Procedures 915,

916, and 920.

The control box, located inside the fan housing, has three separate 

adjustments: 

(1) The low airflow knob adjusts the lower airflow from 40CFM up to 

the air flow rate of the high fan speed determined by the toggle switch 

setting.  

(2) The time delay knob is adjustable from 3 to 30 minutes and will 

switch the fan to the low speed setting after motion is no longer 

detected in the room for the set period of time. 

(3) The toggle switch will adjust the upper fan speed setting from 

90 to 140 CFM .

with 6" duct

WARNING -TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING:

a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer

b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switching 

on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 

c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated 

construction codes and standards. 

d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. 

Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and Air Conditioning   Engineers (ASHRAE), and the local code authorities. 

e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 

f). Ducted fans must always be vented to the outdoors. 

g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only). 

h). This unit must be grounded. 

i). Not for Use in Kitchens.

j). Install Fan At Least 2.5 m (8.2 feet) Above The Floor

k). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or ceilings or into attics, 

crawl spaces, or garages

l).  WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.

m). The fan must not be installed in a ceiling thermally insulated to a value greater R40

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS 

PRODUCT IN A WALL. 

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 

4. Please read specification label on product for further information and requirements. 

   *The manual in electronic format can be download in our company web, or obtained from our dealer.

Max

40CFM

Max

3min

S

T

-

+

-

+

Max.

40CFM 30min

3min

S

T

Cod

0060300727

Содержание PCD110XM

Страница 1: ... a tag to the service panel c Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards d Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufact...

Страница 2: ...ASSEMBLY INSTRUCTIONS 1 Housing mounted to I joists Start at ASSEMBLY INSTRUCTIONS 1 2 Housing mounted to joists Start at ASSEMBLY INSTRUCTIONS 1 3 Housing mounted to truss Start at step ASSEMBLY INSTRUCTIONS 2 2 OPERATION 7 to 9 feet 7 to 9 feet Turn on the switch to activate sensor and continuous ventilation system The fan will run continuously at the pre set low speed When motion is detected th...

Страница 3: ...an housing First insert the sensor plug into the plug base on the power box and then install the grille To attach the grille assembly to the fan housing pinch the grille springs on the sides of the grille assembly and position the grille into the housing with the grille springs in the appropriate slots Push the grille assembly towards the ceiling to secure ASSEMBLY INSTRUCTIONS CONNECT ELECTRICAL ...

Страница 4: ...cement products or parts without charge for any product or part which is found to be defective under normal use This warranty does not cover normal maintenance and service or any parts that have been subject to misuse negligence accident improper maintenance or repair faulty installation or installation contrary to recommended installation instructions S P s obligation to repair or replace at S P ...

Отзывы: