PLAN THE INSTALLATION

1. Do not use in a cooking area.                        2. Two ways to connect ductwork to a factory-shipped unit.

ASSEMBLY INSTRUCTIONS

2

ROOF CAP*

(with built-in

damper)

ROUND

DUCT*

WALL CAP*

(with built-in

damper)

*

 Purchase

separately

POWER

CABLE*

INSULATION*

(Place around and

over Fan Housing.)

Seal gaps

around

Housing.

FAN

HOUSING

ROUND 

ELBOW(S) *

Seal duct

joints with

tape.

Keep duct

runs short

1.Sliding hanger bars have been provided, which allow the 

housing to be positioned accurately anywhere between the 

framing. The bars span up to 24 in. and can be used on all 

types of framing: I-joist, standard joist, and truss construction. 

Slide hanger bars onto housing and adjust as needed to fit 

between framing.

2.Extend the hanger bars to the width of the framing. Position 

the ventilator with the bottom edge of the hanger bar tabs are 

flush with the bottom edge of the framing, holding the ventilator 

in place.Secure hanger bars to framing using one screw on 

each end of hanger bar.Select a proper hole and secure the 

hanger bars together using one screw.

3.INSTALL ROUND DUCTWORK

Connect the round ductwork (not included) to the 

damper/duct connector,and run the ductwork to a 

roof or wall cap (not included). Using tape (not included), 

secure all the ductwork connections so that they are air tight.

The ducting from this fan to the outside of building has a 

strong effect on the air flow, noise and energy use of the fan. 

Use the shortest, straightest duct routing possible for best 

performance, and avoid installing the fan with smaller ducts 

than recommended. Insulation around the ducts can reduce 

energy loss and inhibit mold growth. Fans installed with existing

ducts may not achieve their rated air flow.

Hanger Bar

screw

Содержание PC80XP

Страница 1: ...eans cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards d Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning...

Страница 2: ...sition the ventilator with the bottom edge of the hanger bar tabs are flush with the bottom edge of the framing holding the ventilator in place Secure hanger bars to framing using one screw on each end of hanger bar Select a proper hole and secure the hanger bars together using one screw 3 INSTALL ROUND DUCTWORK Connect the round ductwork not included to the damper duct connector and run the ductw...

Страница 3: ...0 V AC house wiring to the location of the fan Use only UL approved connectors not included to attach the house wiring to the wiring plate Refer to the wiring diagram and connect the wires as shown 3 If adding a Plug and Play Module PCHSP Humidity Sensor PCSCP Speed Control PCMHKP Motion Humidity Sensor etc align the module as shown in the diagram to the right Secure the module to the housing with...

Страница 4: ...IES OF SUITABILITY FOR A PARTICULAR PURPOSE During this five year period S P will at its option repair returned products or parts or provide replacement products or parts without charge for any product or part which is found to be defective under normal use This warranty does not cover normal maintenance and service or any parts that have been subject to misuse negligence accident improper mainten...

Отзывы: