WARNING

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

CLEANING & MAINTENANCE

OPERATION

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off

    power unit.

4. Please read specification label on product for further information and requirements.

For quiet and efficient operation, long life, and attractive appearance - remove grille and vacuum interior of unit

with the dusting brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual 

noises, replace the motor with the exact service motor. The impeller should also be replaced.

Use an on/off switch to operate this fan. See “Connect Wiring” for details

VENTILATION FAN

a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to 

prevent power from being switching on accidentally. When the service disconnecting means cannot be locked, securely 

fasten a prominent warning device, such as a tag, to the service panel. 

c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes 

and standards, including fire-rated construction codes and standards. 

d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning 

equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such 

as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, 

Refrigeration and Air Conditioning   Engineers (ASHRAE), and the local code authorities. 

e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 

f). Ducted fans must always be vented to the outdoors. 

g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected 

branch circuit (ceiling installation only). 

h). This unit must be grounded. 

i). Not for Use in Kitchens.

j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces 

within walls or ceilings or into attics, crawl spaces, or garages

k).  WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed 

Control Device.

l). The fan must not be installed in a ceiling thermally insulated to a value greater than R40.

MODEL:  PC80XP PC110XP PC150XP 

0060302021

*The manual in electronic format can be download in our company web, or obtained from our dealer.

Содержание PC80XP

Страница 1: ...eans cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards d Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning...

Страница 2: ...sition the ventilator with the bottom edge of the hanger bar tabs are flush with the bottom edge of the framing holding the ventilator in place Secure hanger bars to framing using one screw on each end of hanger bar Select a proper hole and secure the hanger bars together using one screw 3 INSTALL ROUND DUCTWORK Connect the round ductwork not included to the damper duct connector and run the ductw...

Страница 3: ...0 V AC house wiring to the location of the fan Use only UL approved connectors not included to attach the house wiring to the wiring plate Refer to the wiring diagram and connect the wires as shown 3 If adding a Plug and Play Module PCHSP Humidity Sensor PCSCP Speed Control PCMHKP Motion Humidity Sensor etc align the module as shown in the diagram to the right Secure the module to the housing with...

Страница 4: ...IES OF SUITABILITY FOR A PARTICULAR PURPOSE During this five year period S P will at its option repair returned products or parts or provide replacement products or parts without charge for any product or part which is found to be defective under normal use This warranty does not cover normal maintenance and service or any parts that have been subject to misuse negligence accident improper mainten...