background image

User Configuration

The STX 165 allows the user to select certain parameters to fit their preferences. It is recommended the user only 

change these configurations when on the ground.  This will keep from interfering with pilot duties and ensure 

uninterrupted response to ATC radar  interrogations.

1. 

To enter the User Set UP mode the STX 165 must be in the SBY (Standby) mode.

2. 

Press and hold the IDT pushbutton while turning and holding the Select knob counterclockwise for 3 
seconds (Note that the select knob will go to a hard stop when rotated approximately an eighth of a turn).  
The display will read “USER SETUP MODE. PRESS ENTER TO CONTINUE.

3. 

Press the Enter pushbutton.  Note that if the Enter Pushbutton is not pressed within ten seconds the STX 
165 will exit the set up mode.

Note: The STX 165 must be in SBY mode to enter the User Set Up 
Function.

The first page displayed when entering the user Set Up mode is ALTITUDE UNIT.  To access subsequent set up 

pages, rotate the Data knob.

TEMP UNIT 

The STX 165 will display temperature in either degrees Fahrenheit or degrees Celsius.  
The factory default setting is Fahrenheit.  To select a different temperature unit:

 

While on the TEMP UNIT page rotate the Select knob counterclockwise to select Celsius 
and clockwise to select Fahrenheit.

ALT UNIT 

The STX  165 can display altitude in either meters or feet.  The category default is feet.  
To select a different altitude value:

 

1. 

Select the ALT UNIT page.

 

2. 

Rotate the Select knob Counterclockwise to select Meters and Clockwise to select  

 Feet.

6

Содержание STX 165

Страница 1: ...STX 165 User Manual 3700 Osuna Road NE Suite 711 Albuquerque NM 87109 www sandia aero 306105 Rev A DRN434...

Страница 2: ...ny means without the prior written consent of SANDIA aerospace Due to SANDIA aerospace s continued product and quality improvement programs information contained in this document is subject to change...

Страница 3: ...ormal display page The power pushbutton is also used to start the counters This is explained in the counter section SBY The STX 165 is in standby mode and will not respond to radar interrogations ON T...

Страница 4: ...unction is useful in high sunlight condi tions particularly with bubble canopies When power is first applied to the STX 165 the SANDIA aerospace logo will be displayed along with the unit version numb...

Страница 5: ...ob and pushbutton Press the Enter Pushbutton the first digit in the squawk code will blink Rotate the smaller Data knob until the value of the codes first digit is displayed Rotate the larger Select k...

Страница 6: ...et Up selection Icing Alert If an optional SANDIA aerospace STP 78 OAT probe is installed with the STX 165 it will display an Icing Alert in the upper right hand corner of the display when the tempera...

Страница 7: ...NT UP at 0 00 Counter Up Counter Down The counter down CNT DOWN allows the pilot to enter a specific time and then be alerted when that time has expired This timer is especially useful for timed appro...

Страница 8: ...ton Note that if the Enter Pushbutton is not pressed within ten seconds the STX 165 will exit the set up mode Note The STX 165 must be in SBY mode to enter the User Set Up Function The first page disp...

Страница 9: ...ended If OFF is selected the pilot will be required to select the ON or ALT Mode The STX 165 starts with the EFT displayed in the lower right hand corner of the display The user can set the EFT to beg...

Страница 10: ...instances a dif ferent code is desirable for the VFR squawk To change the VFR squawk code 1 Rotate the Data knob to select the DEFAULT VFR page 2 Press the Enter knob The brackets will extinguish and...

Отзывы: