16
3700 Osuna Road NE
Suite 711
Albuquerque, NM 87109
www.sandia.aero
volatile memory. The Configuration Page display a yellow box in the upper left hand
corner of the display. DO NOT CYCLE POWER WHILE THIS BOX IS DISPLAYED.
Otherwise, a corruption of the non-volatile memory may occur and the unit will default it’s
configuration.
3.7.2
Configuration Page
Upon entry of configuration mode, the unit displays the following page:
Figure 9-Configuration Screen
Setup Page
Purpose
Min
Value
Max
Value
Increment
VLOC GAIN
Lateral needle gain adjustment
.8
1.2
.001
VLOC OFFSET
Lateral needle zero offset adjustment (10ths of mV)
-2000
2000
1
GS GAIN
Vertical needle gain adjustment
.8
1.2
.001
GS OFFSET
Vertical needle zero offset adjustment (10ths of mV)
-2000
2000
1
TO/FROM
GAIN
TO/FROM input gain
.8
1.2
.001
TO/FROM
OFFSET
TO/FROM zero offset (10ths of mV)
-2000
2000
1
LOC FLAG
GAIN
LOC Flag gain adjustment
.8
1.2
.001
LOC FLAG
OFFSET
LOC Flag zero offset (10ths of mV)
-2000
2000
1
GS FLAG GAIN
GS Flag gain adjustment
.2
1.0
0.01
SWAP
GS Flag zero offset (10ths of mV)
-2000
2000
1
RATIO
Rotor to Stator Transfer Ratio
0.2
1.0
.01
SWAP
Can swap SIN/COS on Stator D/F either 0 or 1.
0
1
1
OBS
Current displayed OBS
1
360
1
OBZ
Electrically Zero OBS
1
360
1
Table 2 - Configuration Parameters
The reading column shows the mV reading on that input. The ELEC column on the ZERO row gives the
electrically output angle on Stator D/F.