USERSMANUALSOFSSG-0007CSSYSTEM

TEMPSkeyS(needStoSbeSusedStogetherSwithS

Skey):S

Press 

 key, the panel will display 

the water temperature set last time and keep flashing: Press 

 key to adjust temperature to highest 

at 42

; press 

 key to adjust temperature to lowest at 10

. It will automatically store and return 

to show the current water temperature after flashing 3 seconds. 

RADIO/AVSkeyS(Radio/DVD/ControlSandSdisplaySofStemperature):

 When the control systems are 

ready to work, first press 

 key, it will go into Radio function, and the panel shows radio channel 

set last time (under Radio status, press 

 key to select pre-stored radio station); second press, 

it will go into TV function (this function is optional), the panel shows TV symbol; third press, it will  

go into DVD function (this function is optional), the panel shows symbols of DVD at the same time  

(Under DVD status, press 

 key to adjust the volume of DVD); press for the fourth time, the 

panel will show the detected water temperature.

TUN/VOLSkeyS (need StoS be Sused S togetherSwith S

S key): S

Under  Radio  status,   first  press 

  key,   the   panel   will   show   2-digit   volume,   press  

  can   adjust   volume   upwards   or 

downwards (the panel will automatically show radio frequency when stop adjusting for 3 seconds). 

Second press 

the current frequency will flash, press 

S

key to adjust the current frequency , 

it will store automatically after flashing 3 seconds. Third press, the panel will show radio channel,  

press  

  key to select pre-stored radio station ( the panel will automatically show previous  

radio   frequency   when   stop   adjusting   for   3   seconds).   Long   press   for   5   seconds,   the   system   will 

automatically  search   radio   frequency  again   and   store   the   searched   frequency  at   different   channel 

sequentially.

HeatingSsystem:S

After the control systems are ready to work, the heater will start working 10 seconds 

after the circulation pump is activated unless the temperature sensor detect that the set temperature is  

lower than the detected one. When the water temperature reach set temperature, the heater will stop  

working automatically. When the water temperature is under 2

 of the preset one, the heater will be

 

activated to work again.

REMARK:S

The heater will not be activated to work if there is not enough water flow trans-fluxing it. 

InterlockedSsystemSbetweenSheaterSandSpumps:

S

Long press             key again for 20 seconds, the 

system can be converted between interlock mode or non-interlock mode (the indicator light on 

 

key shows 

REDS

under interlock mode; while it shows

SGREENS

under non-interlock mode). When it 

is in interlock mode, the heater will stop when you press any key of pumps and bubble. This feature is  

to reduce the power needed for the spa so that it can match the power limit of some countries. In non-

interlocked mode, the heater will keep running when the other pumps are activated unless the water 

temperature reaches the set temperature.

Temperature S sensor’s S self-checking S system:

  When   the   panel   shows   EO   which   means   the 

3

Содержание SG-0007C

Страница 1: ...instruction on it connect the power supply correctly If the power supply is 220V 50HZ the wires serving as equipotential bonding conductors shall have a cross sectional area not less than 3 10mm2 If the power supply is 380V 50HZ the wires serving as equipotential bonding conductors shall have a cross sectional area not less than 5 6mm2 The protection system should be based on a residual current de...

Страница 2: ...s working its symbol will be displayed on the panel too Meanwhile the panel will display the detected water temperature which will refresh once every 60 seconds PUMPSkey Spress PUMP1 key its symbol will show on the panel Pump1 will be activated press PUMP2 key its symbol will show on the panel Pump2 will be activated PUMP 2 is optional for some models press PUMP3 key its symbol will show on the pa...

Страница 3: ...s Third press the panel will show radio channel press key to select pre stored radio station the panel will automatically show previous radio frequency when stop adjusting for 3 seconds Long press for 5 seconds the system will automatically search radio frequency again and store the searched frequency at different channel sequentially HeatingSsystem SAfter the control systems are ready to work the...

Страница 4: ...about 85 seconds and stop finally comes for Pump 3 if equipped working for about 85 seconds then stops Pump1 Pump2 and Pump3 will continuously cycle among them When the detected water temperature reaches 10 all the pumps and heater will stop working When this system is running the screen background light is on When the water temperature reaches 10 the screen returns to the standby status Remark Wh...

Страница 5: ...overheat protection function When the water in spa reaches to 43 some parts stop working and OH shows on the screen The above parts includes air blower heater and all massage pumps When the temperature down to 40 OH disappears The functions can be used as normal by controling the control panel Screen protection function The backlight of screen will be turned off after 1 minute switching on the con...

Страница 6: ...ituations rinse and dry with a soft cloth V SInstructionsStoSdrainStheSwaterS 1 Open the skirt panel of drain valve to open the red ball valve the ball valve connecting to the black drain valve is closed when it is out of factory 2 Take out the small plug and then connect a hose to it Loose the drain vale anticlockwise to open the drain valve and the water will come out After finishing draining sc...

Отзывы: