USERSMANUALSOFSSG-0007CSSYSTEM

CarefullySreadSallSofStheSinstructionsSbeforeSenjoyingStheSspa.

WARNING:

 Operating the system without water will cause severe damage. 

WARNING:

 SHOCK HAZARD! No user serviceable parts. Do not attempt to service this control. Contact your  

dealer or service center for assistance. Follow all user’s manual power connection instructions. Installation must  

be performed by a certified licensed electrician and all grounding connections must be properly installed. 

I.SInstallation

1)

Please open the tub skirt according to instruction on it, connect the power supply correctly. If the power 

supply   is   220V/50HZ,   the   wires   serving   as   equipotential   bonding   conductors   shall   have   a   cross  

sectional   area   not   less   than   3×10mm

2

.   If   the   power   supply   is   380V/50HZ,   the   wires   serving   as 

equipotential bonding conductors shall have a cross sectional area not less than 5×6mm

2

.The protection 

system should be based on a residual current device (RCD). Be sure that the earth cable connection is  

correctly made. The circuit diagram of hot tub is shown as following. (Fig 1)

(FigS1)

2)

Before infuse water into hot tub for using, please check the valve for each pipeline. The hot tub’s drain  

valve must be in normal close while valves for other pipeline must be in normal open. After confirm  

1

Содержание SG-0007C

Страница 1: ...instruction on it connect the power supply correctly If the power supply is 220V 50HZ the wires serving as equipotential bonding conductors shall have a cross sectional area not less than 3 10mm2 If the power supply is 380V 50HZ the wires serving as equipotential bonding conductors shall have a cross sectional area not less than 5 6mm2 The protection system should be based on a residual current de...

Страница 2: ...s working its symbol will be displayed on the panel too Meanwhile the panel will display the detected water temperature which will refresh once every 60 seconds PUMPSkey Spress PUMP1 key its symbol will show on the panel Pump1 will be activated press PUMP2 key its symbol will show on the panel Pump2 will be activated PUMP 2 is optional for some models press PUMP3 key its symbol will show on the pa...

Страница 3: ...s Third press the panel will show radio channel press key to select pre stored radio station the panel will automatically show previous radio frequency when stop adjusting for 3 seconds Long press for 5 seconds the system will automatically search radio frequency again and store the searched frequency at different channel sequentially HeatingSsystem SAfter the control systems are ready to work the...

Страница 4: ...about 85 seconds and stop finally comes for Pump 3 if equipped working for about 85 seconds then stops Pump1 Pump2 and Pump3 will continuously cycle among them When the detected water temperature reaches 10 all the pumps and heater will stop working When this system is running the screen background light is on When the water temperature reaches 10 the screen returns to the standby status Remark Wh...

Страница 5: ...overheat protection function When the water in spa reaches to 43 some parts stop working and OH shows on the screen The above parts includes air blower heater and all massage pumps When the temperature down to 40 OH disappears The functions can be used as normal by controling the control panel Screen protection function The backlight of screen will be turned off after 1 minute switching on the con...

Страница 6: ...ituations rinse and dry with a soft cloth V SInstructionsStoSdrainStheSwaterS 1 Open the skirt panel of drain valve to open the red ball valve the ball valve connecting to the black drain valve is closed when it is out of factory 2 Take out the small plug and then connect a hose to it Loose the drain vale anticlockwise to open the drain valve and the water will come out After finishing draining sc...

Отзывы: