REDOX controlling unit using guide

 

 
 
1  Display of REDOX amount 
 
2  Switch for measured amount / set point amount 
 
3  Switch status of electrical socket 
 
4  Adjustment of set point 
 
5  Socket power adapter 
 
6  BNC connector for REDOX electrode 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
7  REDOX electrode with cable 
 
8  Connecting cable for REDOX to Ozonizer 
 
9  Bracket for REDOX electrode 
 
10  Screw Driver 
 
11  Cleaning Brush 
 
12  Bottle 

 
Technical Data

 

 
Range of usage: 

 

0 bis 1000 mV 

Power supply: 

 

12 VDC 

Current consumption: 

100 mA 

max. Switching capacity: 

12 VDC / 4A 

 

Contents of delivery 
 

Before starting the unit, check whether the following delivery contents are complete and 
undamaged: 
 
1 x Redox potential measuring and regulating unit, 1 x REDOX electrode with cable, 
1 x Connecting cable for Ozonizer, 1 x Bracket for REDOX electrode, 1 x Screw Driver,    
1 x Cleaning Brush, 1 x Bottle for cleaning fluid and 1 x REDOX controlling unit Instruction booklet. 

Содержание REDOX

Страница 1: ...Instructions for Use REDOX Potential Measuring and Regulating Unit...

Страница 2: ...ng unit is characterized for use only with corresponding ozone generators of our product line items Certizon S XT and P The device was synchronized specifically for use with the mentioned products and...

Страница 3: ...iver 11 Cleaning Brush 12 Bottle Technical Data Range of usage 0 bis 1000 mV Power supply 12 VDC Current consumption 100 mA max Switching capacity 12 VDC 4A Contents of delivery Before starting the un...

Страница 4: ...it is damaged please do not operate it without having it checked Damaged Devices may be an unnecessary and considerable danger to the owner Warranty and liability information All of the REDOX potentia...

Страница 5: ...nd S A Sander ozone generator of the product line item Certizon or S should be connected using the delivered connecting cable for REDOX Ozonizer 8 The REDOX measuring and regulating unit works with th...

Страница 6: ...mitting diode and the power tension are automatically switched on Usage cleaning and maintenance of the REDOX potential electrode When in everyday use the safety cap on the electrode foot must be take...

Страница 7: ...ong with the package and fill it one third of the bottle with the citric acid Fill up the rest with tap water Screw the electrode off the measuring unit and dip it into the cleaning fluid for three mi...

Страница 8: ...In interest of general environmental protection do not dispose of the device in domestic garbage but provide for an appropriate way of disposal You can be informed about garbage collecting places and...

Отзывы: