Sanden Heat Pump – Installation Manual 

Page 26 of 28 

Check sheet  

Safety items 

Action 

Completed 

Fix  the  legs  of  the  tank  unit  in  place  with  anchor 
bolts if necessary. 

 

The  floor  has  been  properly  waterproofed  and 
properly drained. 

 

The earth leakage breaker can be turned off with the 
test button. 

 

Earth (ground) work is implemented. 

 

The tank unit is installed on a level sturdy surface. 

 

There are no gas containers or flammable materials 
anywhere near the unit. 

 

The wiring between the tank unit and the heat pump 
unit is properly connected. 

 

Around units 

Action 

Completed 

A concrete base block is installed (if necessary). 

 

An  inspection  space  is  retained  in  accordance  with 
the installation manual 

 

Around the piping 

Action 

Completed 

A dedicated water supply/stop cock is mounted. 

 

The metal  piping  for  the hot  water  supply has been 
properly insulated. 

 

There is no water leaking from the water supply/hot 
water supply and heat pump pipes. 

 

Pipe insulation Protection is provided. 

 

Union joints are used so that the parts can be easily 
removed. 

 

Piping  is  installed  from  the  drain  outlet  and  drain 
hopper to the drain ditch. 

 

The filter in the pressure-reducing valve is clean. 

 

Independent pipes, not a twin tube, are used for the 
heat pump unit pipes (insulated, UV stabilised) 

 

The  drainage  hose  from  the  heat  pump  unit  leads 
into the drain ditch. 

 

Pressure  reduction  valve  (500kPa)  has  been  fitted 
to the cold water supply of the unit 

 

During  draining  of  the  tank,  unit  water  does  not 
overflow from the drain ditch. 

 

 
 

Installed By…………………………………………………… Date………………………………… 

 

 

 

Inspected By …………………………………………………. Date………………………………… 

Содержание GAUS-315QT

Страница 1: ...3 45HPA AU This appliance is not to be used by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervisi...

Страница 2: ...0 Change of water supply 20 Technical data 21 Warranty Policy 24 Warranty Period 25 Post installation inspection checklist 25 Check sheet 26 MEMO 27 PATENTS This water heater may be protected by one o...

Страница 3: ...currently available It s even more efficient when connected to off peak power1 and the noise level is so low it will operate unobtrusively throughout the night How it works The Sanden Eco Hot water H...

Страница 4: ...the relevant standards Only a licensed person will have insurance protecting their workmanship for six years The unit has been specifically designed for domestic hot water heating and is not suitable...

Страница 5: ...o circulate and provide adequate space for service maintenance of the unit Figure 3 Install the heat pump unit in an area which allows sufficient ventilation Poor ventilation may cause the unit to sho...

Страница 6: ...unless there is a likelihood of high wind or local vibration If the heat pump unit and tank unit are fixed appropriate fixing devices should be used A pressure and temperature relief PTR valve is incl...

Страница 7: ...s product cannot be connected to a solar water heater The piping must be insulated using insulation having a thermal conductivity no greater than 0 04 W m K and minimum thickness of 25 mm If the pipin...

Страница 8: ...supply to the lower fitting on the tank unit marked Cold Water Inlet Connect the hot water supply pipe to the top of the tank unit marked Hot Water Outlet Install the supplied PTR valve to the fitting...

Страница 9: ...o places on the heat pump unit Close the plugs after no air is confirmed in the water Connect the power to the heat pump unit and leave a hot water tap open in the home for three minutes Close the hou...

Страница 10: ...Wrap the freeze protection heater up to the water connectors of the main unit Ensure the freeze protection heaters are connected to 24 hours continuous power supply It is important to fully explain ho...

Страница 11: ...r supply is cut off However the system will automatically start operation once the electricity becomes available System operation if connected to off peak electricity There are no special settings for...

Страница 12: ...cover terminal block cover and screw clamp fitting Connect the power supply line to the terminal block Hold the power supply line below the terminal block with the screw clamp fitting Attach the termi...

Страница 13: ...the grey cable inside the black conduit Expose the 2 thermistor wires black white Note that wires from thermistor in tank are black black Strip the 2 wires ready for the terminal block remove the fin...

Страница 14: ...ck Setting Mode Press the Enter key in the Clock Display Mode to switch to the Clock Setting Mode Time Display starts flashing once the mode is switched 2 Setting the Clock The time setting can be adj...

Страница 15: ...Heat Pump Installation Manual Page 15 of 28 Figure 12 How to operate the controller How to remove the operation panel Remove Top Panel 6 screws Pull up Operation Panel Pull up Operation Panel Operatio...

Страница 16: ...tops flashing The end time display starts flashing at the same time Adjust block out end time Set to the desired end time by using Up and Down keys Setting can be performed only in hour increments not...

Страница 17: ...Check the values measured by the thermistor How to switch to Maintenance Mode Press and hold down Up and Down keys together in the clock display mode to go to the maintenance mode After the mode is sw...

Страница 18: ...e open If the water circulation pump is not working replace the pump E002 HP water outlet over temperature 2 E003 HP outlet temperature thermistor detection error Check if the thermistor is out of the...

Страница 19: ...thermistor wire short circuit E023 HP discharge temperature thermistor wire short circuit E024 HP defrost temperature thermistor wire short circuit E025 HP ambient temperature thermistor wire short c...

Страница 20: ...ntaminants Water with a pH less than 6 0 may be treated to raise the pH It is recommended that an analysis of the water from a rainwater tank be conducted before connecting this type of water supply t...

Страница 21: ...ity 4 5 kW 1 Power consumption Mid Winter Season 0 91 kW 1 1 03kW 2 COP Mid Winter Season 5 0 1 4 4 2 Circuit Breaker Size 20A Design Pressure High Low 14 9 0MPa Protection Raining Class IPX4 Max Oper...

Страница 22: ...Sanden Heat Pump Installation Manual Page 22 of 28 Hot water storage tank unit REFER Drawing provided with tank GAUS 315EQS Model No GAUS 315EQT GAUS 250EQTB GAUS 160EQTB...

Страница 23: ...Sanden Heat Pump Installation Manual Page 23 of 28 Wiring Diagram...

Страница 24: ...rdance with the guidelines in the Sanden Heat Pump Water Heater System literature Warranty Exclusions 1 Repair and replacement work will be carried out as set out in the Sanden Heat Pump Water Heater...

Страница 25: ...other modes of failure Warranty Period Subject to the Warranty Conditions and Exclusions stated above your Sanden Heat Pump Water Heater System is warranted in a Residential application as follows Hea...

Страница 26: ...h the installation manual Around the piping Action Completed A dedicated water supply stop cock is mounted The metal piping for the hot water supply has been properly insulated There is no water leaki...

Страница 27: ...Sanden Heat Pump Installation Manual Page 27 of 28 MEMO...

Страница 28: ...Sanden Heat Pump Installation Manual Page 28 of 28 SANDEN Heat Pump 40980 44912 Installation Manual AU...

Отзывы: