Sanden GAUS-315EQTA Скачать руководство пользователя страница 14

 

Sanden

 

Heat

 

Pump

 

 

Owner’s

 

Manual

 

Page

 

14

 

of

 

16

 

Warranty

 

Policy

  

 
Warranty Conditions 

1.  The Sanden Heat Pump Water Heater System must be installed in accordance with 

the installation instructions supplied with the Heat Pump Water Heater System and 
in accordance with all relevant statutory and local requirements of the state in which 
the water heater is installed. 

2.  Where a failed component or Heat Pump Water Heater System is replaced under 

warranty, the balance of the original warranty period will remain effective. The 
replaced part or Heat Pump Water Heater System does not carry a new warranty. 

3.  Where the Heat Pump Water Heater System is installed outside the boundaries of a 

metropolitan area as defined by Sanden or further than 25 kilometers from an 
accredited service agent, the cost of transport, insurance and travelling costs 
between the nearest accredited service agent's premises and the installed site shall 
be the owner's responsibility. 

4.  Where the Heat Pump Water Heater System is installed in a position that does not 

allow safe, ready access, the cost of accessing the site safely, including the cost of 
additional materials handling and/or safety equipment, shall be the owner's 
responsibility. 

5.  The warranty only applies to the Heat Pump Water Heater System and original or 

genuine (company) component replacement parts and therefore does not cover any 
plumbing or electrical parts supplied by the installer and not an integral part of the 
Heat Pump Water Heater System. Such parts would include pressure limiting valve, 
isolation valves, non-return valves, electrical switches, pumps or fuses. 

6.  The Heat Pump Water Heater System must be sized to supply the hot water 

demand in accordance with the guidelines in the Sanden Heat Pump Water Heater 
System literature. 

 

Warranty Exclusions

 

1.  Repair and replacement work will be carried out as set out in the Sanden Heat 

Pump Water Heater System warranty. However the following exclusions may void 
the warranty and may incur a service charge and/or cost of parts: 

2.  Accidental damage to the Heat Pump Water Heater System or any component, 

including: Acts of God, failure due to misuse, incorrect installation, attempts to 
repair the water heater other than by a Sanden accredited service agent or the 
Sanden service department. 

3.  Where it is found there is nothing wrong with the Heat Pump Water Heater 

System; where the complaint is related to excessive discharge from the 
temperature and/or the pressure relief valve due to high water pressure; where 
there is no flow of hot water due to faulty plumbing; where water leaks are related to 
plumbing and not the Heat Pump Water Heater System or its components; where 
there is a failure of electricity or water supplies; where the supply of electricity or 
water does not comply with relevant codes or acts. 

4.  Where the Heat Pump Water Heater System or its component has failed directly or 

indirectly as a result of excessive water pressure. 

5.  Overflow vent drain has not been installed or blocked or corroded  
6.   Where the Heat Pump has rusted as a result of a corrosive atmosphere; 
7.  Where the unit fails to operate as a result of ice formation in the pipe work to or from 

the Heat Pump Water Heater System. 

 

Содержание GAUS-315EQTA

Страница 1: ...GAUS 315EQTA Heat Pump Unit GAU A45HPA Tank Unit GAU 315EQTA Owner s manual Heat Pump Unit GAU A45HPA Tank Unit GAU 315EQTA...

Страница 2: ...upply quality 11 Change of water supply 11 Dimensions and technical data 12 Warranty Policy 14 Warranty Period 15 Registration for warranty 16 PATENTS This water heater may be protected by one or more...

Страница 3: ...energy efficient units currently available It s even more efficient when connected to off peak power1 and the noise level is so low it will operate unobtrusively throughout the night How it works The...

Страница 4: ...Sanden Heat Pump Owner s Manual Page 4 of 16...

Страница 5: ...Sanden Heat Pump Owner s Manual Page 5 of 16...

Страница 6: ...the unit not being guaranteed Anywhere the lowest temperature reached is under minus 10 degrees centigrade Indoors Applies only to the heat pump unit Anywhere not completely flat unstable or where dr...

Страница 7: ...ies with all the relevant standards Only a licensed person will have insurance protecting their workmanship for six years The unit has been specifically designed for domestic hot water heating and is...

Страница 8: ...for about 1 hour Consider a change of the electricity supply off peak mode Length of power supply hours may be too short for the water heating cycle to cover the hot water consumption Air removing pr...

Страница 9: ...7 Replace the inside cover and the end cover Do NOT attempt to open the system for any reason such action will nullify the warranty If any other fault occurs or is recognised you must contact your sup...

Страница 10: ...trical power supply is cut off i e if it is connected to off peak power However the system will automatically start operation once the electricity becomes available System operation if connected to of...

Страница 11: ...contaminants Water with a pH less than 6 0 may be treated to raise the pH It is recommended that an analysis of the water from a rainwater tank be conducted before connecting this type of water supply...

Страница 12: ...ge 12 of 16 Dimensions and Technical Data Hot Water Storage Tank unit GAU 315EQTA Storage Capacity 315 litres Product Weight 89 4 kg Design Pressure 700 kPa Storage Tank Material Stainless Steel Outsi...

Страница 13: ...6 Heat Pump Unit GAU A45HPA Refrigerant Type R744 CO2 Product Weight 56 kg Thermal Capacity 4 5 kw 1 Power Consumption 1 0 kw 1 COP 4 5 1 Heated Water Temp 65 o C 1 Ambient Temp Dry Wet 16o C 17o C In...

Страница 14: ...uld include pressure limiting valve isolation valves non return valves electrical switches pumps or fuses 6 The Heat Pump Water Heater System must be sized to supply the hot water demand in accordance...

Страница 15: ...water heater has been connected to a scaling or corrosive water supply or a water supply with a high chloride or low pH level as outlined in the Owner s Guide and Installation Manual Subject to any st...

Страница 16: ...bel on right end ____________________________ Hot Water Tank Serial Number label on tank ________________________________ Date of Purchase Installation ________ _______ 20_____ Suppliers Name ________...

Отзывы: