U0
Refrigerant leakage error
- Measure resistance of each thermistors.
- Measure resistance of coil of expansion vale to
check open or short circuit.
- Replace the main PCB or heat pump.
E1
Main PCB error
- Replace the main PCB.
E2
L7
Control PCB error
- Replace the
control
PCB.
F5
Communication error between
main PCB to control PCB
- Check the
communication
connector on the
main PCB and control PCB.
- Replace the main PCB or control PCB.
E8
High inlet current error
- Check the installation location.
- Check the supply voltage.
- Replace the main PCB or heat pump.
H8
Current error
- Replace the main PCB.
L4
High temperature of module error
- Check the installation location.
- Remove foreign objects from the evaporator
coil (e.g. fallen leaves, grass, snow)
- Check the Fan motor is not flowing by dirt.
- Replace the main PCB or fan motor.
L5
High outlet current error
- Measure resistance of the discharged
thermistor.
- Measure resistance of coil of expansion vale to
check open or short circuit.
- Replace the main PCB or heat pump.
P4
Module temperature thermistor error
- Replace the main PCB.
U2
High voltage error
- Check the supply voltage.
HJ
Water circuit error
- Check the inlet water valve.
- Check for any piping bend, blocking, kink or
frozen.
- Measure resistance of each Thermistor.
- Measure resistance of coil of expansion vale to
check open or short circuit.
- Replace the main PCB or heat pump.
EC
High water outlet error
- Check the water circuit is not flowing by air, dirt
or scaling.
- If the water circulation pump is not working,
replace the pump.
- Measure resistance of water outlet thermistor.
- Replace the main PCB.
E9
Water pump error
- Check the water is full fill in the Tank.
- If the water circulation pump is not working,
replace the pump.
- Check the revolution of pump by controller. If
the revolution is low, replace the pump.
- Replace the main PCB
E7
Fan motor locked
- Remove foreign objects around the fan motor.
- Check the fan motor connectors on the main
PCB.
- Replace the main PCB.
Содержание GAUS-160FQS
Страница 23: ...Sanden Heat Pump Installation Manual Page 23 of 32 Hot water storage tank unit REFER Drawing provided with tank...
Страница 24: ...Sanden Heat Pump Installation Manual Page 24 of 32 315L 300L 250L 160L...
Страница 25: ...Sanden Heat Pump Installation Manual Page 25 of 32 Wiring Diagram...
Страница 29: ...MEMO...
Страница 30: ......
Страница 31: ......
Страница 32: ...SANDEN Heat Pump 40980 44913 Installation Manual AU...