Sandel
Avionics
SN3308 Navigation Display
Installation Manual
90106-IM-G(4) Installation Manual W SIG.doc
Appendix-A Page 19
17: SYSTEM LCD SETUPS
CONSULT FACTORY
SET LEFT POS
000
SET TOP POS
198
TRIM BOT POS
541
TRIM RT POS
458
TRIM T/B CENT
314
TRIM L/R CENT
232
LCD SHP
003
LCD PLL
065
LCD TC1
050
Notes
:
These settings should be changed only on instructions from the
factory, service bulletin, or service information letter.
18: SYSTEM
I/O Rev
1
CPU
Rev
0
INTERNAL
TEMP
30
q
C
85
q
F
FAN
RPM
6600
INVERTER INPUT
400 Hz
INVERTER
Vp-p 36.00
COLOR
SELECT PILOT
400
Hz
INVERTER DISABLED
BOOTSTRAP
OUT ENABLED
WX DETECTION
OFF
Purpose
:
Shows some helpful system diagnostics.
IO/CPU Rev:
These are informational showing the revision level of the internal
circuit boards. These numbers are NOT the same as the MOD
LEVEL information on the data plate.
Temp:
Internal temperature is displayed for determination of proper
installation cooling. The internal temperature should run
approximately 10
q
C or 18
q
F above ambient temperature after
operating for 30 minutes at maximum brightness. If due to