Setup Procedures
82011-IM, REV J
Sandel SG102 & MT102 Installation Manual
Page 6-1
6
Setup Procedures
6.1
Software Configuration
6.1.1 SG102 Maintenance Adapter (USB) p/n 81032
The Sandel 81032 SG102 Maintenance Adapter is available to allow USB communication
between the setup PC and the SG102 in order to operate the Installation-Calibration software.
See the Maintenance Adapter User Guide for instructions for use.
6.1.2 SG102 Installation-Calibration Utility Software
Sandel 82011-ICU Installation-Calibration Utility software is used in conjunction with the
81032 SG102 Maintenance Adapter to support the following functions:
•
View the serial number and software version of the SG102 and MT102.
•
Selecting the default SG102 mount orientation.
•
Compass calibration.
•
Selecting Arinc 429 enhanced maintenance labels.
•
Selecting Arinc 429 Hi/Low Speed. For SG102 (MOD 2) and SG102/D
See 82011-ICUG (SG102 Installation Calibration Utility User Guide) for use of this software.
Any time changes are made to the SG102 setup or calibration, an entry must be made in the
aircraft maintenance logs by an appropriately rated person stating the action taken.
6.1.3 Mounting Orientation Select
The 82011-ICU Installation-Calibration Utility software is used to select the mounting
orientation. Follow the instructions in the User Guide.
NOTE: If the correct software orientation selection is not made the SG102 will appear to
operate properly on the ground but will malfunction during flight.