22
S&C Instruction Sheet 811-510
Assembling the Loadbuster Loadbreak Tool
Step 44
For Loadbuster Loadbreak Tool Catalog Number 5300R3-E,
install the extended insulating hood. See Figure 49.
Extended insulating hood
Figure 49. For Loadbuster Loadbreak Tool Catalog 5300R3-E,
install the extended insulating hood.
Step 45
After reassembly, reset the Loadbuster Loadbreak Tool.
Hold with the inner tube extended, and lift the resetting
latch with your thumb. With the latch up, press down on the
inner tube assembly until the tool is closed completely so
the trigger can reset itself. When reset properly, the orange
inner tube will no longer be visible.
Check for proper resetting by extending the tool about
three inches (76 mm) until you feel increasing spring resis-
tance. Operate the tool several times to make sure the trig-
ger and resetting latch perform properly. Refer to Instruc-
tion Sheet 811-505 for complete operation instructions.
Step 46
Make sure the trip force is between 20 and 27 lbs. for
Loadbuster Loadbreak Tool 5300R3 (20 to 29 lbs. for
Loadbuster Loadbreak Tool 5400R3) by securing the hook
frame assembly and pulling open the tool using a force
gauge attached to the anchor assembly.