Specifications 

Standard

 

IEEE 802.3 10Base-T, 802.3u 100Base-TX and 100Base-FX standards 

 

IEEE 802.3x Flow Control & Back Pressure 

OPTICAL 
PORT

 

 

Multimode 

Single Mode 

Wavelength (nm) 

850 

1310 

1310 

1550 

Distance (Km) 

0 to 2 

0 to 5 

0 to 120 

0 to 120 

Transmit Power ( dbm) 

-5 to -18 

-5 to -18 

-12 to 0 

-12 to 0 

Sensitivity ( <dbm) 

-28 

-32 

-35 

-35 

Optical Saturation (dBm) 

-3 

-3 

-3 

-3 

Optical Loss (dBm/Km) 

-3 

0.5 

0.4 

0.25 

Fiber Cable (µm) 

50/62.5-125, 100/140 

8.3, 8.7, 9, 10/125 

Connector 

SC, ST, FC 

Data Rate 

155M 

Ethernet 
Port

 

Data Rate 

10/100 Mbps 

MAC Address 

1K 

Buffer 

288Kb 

Connector 

RJ45 

Isolation 

1.5KV Magnetic 

Power 

Power 

12 to 48V DC, 200mA. 3 Pin screw type terminal 

Wattage 

2.5 W 

Lightening Protection 

5KA 

Reverse Polarity Protection 

Yes 

Overload Protection 

Yes 

Operating 
Conditions

 

Temperature Operating 

-40 to 85°C 

Temperature Storage 

-55 to 110 °C 

Humidity 

5 to 95% non condensing 

Mechanicals

 

Mounting 

DIN Rail 

Dimensions (mm) 

100 * 81 *35 

Weight 

360g 

Class 

IP30 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание SC12FEIS

Страница 1: ... Certificate 4 Power terminal block and Din Rail Features 1 Ethernet Port 1 Fiber port Auto Negotiation in TP port Auto Crossover for MDI MDIX in TP port Store and forward Switching mechanism Broadcast Storm Flow Control on Full Duplex Back Pressure on Half Duplex Full or Half Duplex on both copper and fiber Port Details All ports on this unit support automatic MDI MDI X operation you can use stra...

Страница 2: ...will light up Please refer to the LED Indicators section for meaning of LED lights Prepare the twisted pair straight through Category 5 cable for Ethernet connection Insert one side of Category 5 cables into the Ethernet port RJ 45 port and another side of category 5 cables to the network devices Ethernet port RJ 45 port ex switch PC or Server The UTP port RJ 45 LED on the unit will light up when ...

Страница 3: ...PWR Green ON Power supply ON OFF Power supply OFF FDX Optic port indicator ON Connect OFF Not connected 10M 100M Green ON 100Base TX OFF 10Base T Link ACT Yellow ON Network connected Blink Network communication OFF No network connected Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the unit Insert the top of DIN Rail into the track Then lightly push the DIN Rail into the track ...

Страница 4: ...2 to 0 12 to 0 Sensitivity dbm 28 32 35 35 Optical Saturation dBm 3 3 3 3 Optical Loss dBm Km 3 0 5 0 4 0 25 Fiber Cable µm 50 62 5 125 100 140 8 3 8 7 9 10 125 Connector SC ST FC Data Rate 155M Ethernet Port Data Rate 10 100 Mbps MAC Address 1K Buffer 288Kb Connector RJ45 Isolation 1 5KV Magnetic Power Power 12 to 48V DC 200mA 3 Pin screw type terminal Wattage 2 5 W Lightening Protection 5KA Reve...

Страница 5: ...a Phone 91 20 65001587 9764027070 8390069393 Connecting Converting Leading email info santelequip com LFP Link Fault Pass through details Product Selection Code SC12FEIS M S SC ST FC SC12FEIS Standard Model Code Mode M Multimode S Single mode Connector SC SC ST ST FC FC ...

Отзывы: