23 

 

 

If the gateway cannot contact a DHCP Server, the gateway will use the last good IP address it 
was configured with.  

 

4.15.3 Obtain IP address to the PC or laptop using DHCP server 
 

The gateway can be used as a DHCP Server to allocate an IP address to a PC or Laptop that 
you want to use to connect with Ruinet to the gateway.  
 

i)  Enable the DHCP Server on Ethernet port N1 by pressing 

“5”. 

 

 

ii) Press 

“Y” <Enter> 

to enable. 

“N” 

will disable the DHCP Server.  

 

iii) Press any key to continue and escape back to the main menu. Press

”!” 

to restart 

the gateway.  
 
When connecting a PC or Laptop to the gateway on port N1,be sure to enable the DHCP 
Client function on the PC or Laptop. The following screen-shot from the Network Connection’s 
properties on a Windows PC shows the TCP/IP settings needed to enable the PC’s DHCP 
Client:  
Select TCP/IP and then properties  
 

 

 

Simply restart the PC while connected to the gateway and it will obtain an IP address from the 
gateway.  
 
 
 
 

Содержание GW BMS

Страница 1: ...San Telequip P Ltd 504 505 Deron heights Opp Mahabaleshwar hotel Baner Road Baner Pune 411 045 Phone 020 65001587 Connecting Converting Leading email info santelequip com 1 USER MANUAL FOR GW BMS...

Страница 2: ...rting Leading email info santelequip com 2 Table of Contents 1 INTRODUCTION 3 2 SPECIFICATIONS 3 3 OPERATION 4 4 REMOTE USER INTERFACE 4 5 USE THE WEB GUI TO CONNECT TO THE GATEWAY 25 6 NAVIGATION TRE...

Страница 3: ...to the gateway 2 SPECIFICATIONS Interfaces Serial Interface SERIAL PORT 1 RS 485 2 Wire 3 Pin Screw type terminals RS 485 4 Wire 5 Pin Screw type terminals For GW BMS 01 GW BMS 02 SERIAL PORT 2 Optio...

Страница 4: ...aster Slave Metasys N2 Client Server GW BMS 04 BACnet MSTP Master Slave Metasys N2 Client Server Metasys N2 Master Slave BACnet IP Client Server 7 SNMP Client Server to BACnet IP Client Server GW BMS...

Страница 5: ...sed 1 Connect the ethernet straight cable between gateway and PC 2 Gateway is assigned default IP address as 192 168 1 200 Please set the IP address to PC that is compliant with subnet of gateway s su...

Страница 6: ...com 6 In the Main Menu Section following options are available to select 4 3 B Fieldserver Information Press B key to access the screen displaying general information about the gateway 4 4 P Enable D...

Страница 7: ...on Login as Admin Admin privileges allow full access to all screens and changes to information Login as User User privileges allow read only access i e browsing between screens but no changes can be m...

Страница 8: ...current connection out of the total number of connections N1 Network Adapter N1 S1 N1 Port Adapter Protocol Protocol specified as per the Port Adapter Tx Msg Transmitted Messages Rx Msg Received Mess...

Страница 9: ...the number of nodes with names configured in configuration file Tx Msg Transmitted Messages at specified node Rx Msg Received Messages at specified node Tx Char Transmitted Characters at specified no...

Страница 10: ...cified Map descriptor Errors Displays the number of errors for each Map descriptor Occasional errors may indicate noise but may also indicate a systematic error 4 8 A Data Array Overview Press key A i...

Страница 11: ...eading email info santelequip com 11 4 9 L Message Log Press L in Main Menu to enter Message Log menu Following window will be open This screen shows normal informational type messages from the operat...

Страница 12: ...mail info santelequip com 12 If errors are not present then in window No Errors message will be displayed 4 11 F Driver Log Press F key into Main Menu to enter in Driver Log menu Informational type me...

Страница 13: ...yed on this screen 4 13 D Download configuration 1 For preparing configuration file technical details like baud rate settings slave device IDs modbus mapping should be given to the Santelequip After o...

Страница 14: ...P Ltd 504 505 Deron heights Opp Mahabaleshwar hotel Baner Road Baner Pune 411 045 Phone 020 65001587 Connecting Converting Leading email info santelequip com 14 3 Press 1 key to enter into the main m...

Страница 15: ...oad Baner Pune 411 045 Phone 020 65001587 Connecting Converting Leading email info santelequip com 15 4 Press D key to go to the download screen 5 Press L to specify the configuration file name Enter...

Страница 16: ...cape key twice to go back to the main menu and restart the BMS gateway by pressing Shift 1 key 8 Wait till gateway gets restarted 9 Close the Ruinet exe file after detecting the IP address of the gate...

Страница 17: ...020 65001587 Connecting Converting Leading email info santelequip com 17 4 14 U Upload configuration 1 Press U key into Main Menu following window will open 2 Press L for Local PC filename Then type...

Страница 18: ...be shown on screen 4 Press Esc key to go back into main menu File is saved at given specific drive in the PC 4 15 1 I Change IP Address 1 Gateway is assigned default IP address as 192 168 1 200 Pleas...

Страница 19: ...hone 020 65001587 Connecting Converting Leading email info santelequip com 19 3 Press 1 key to enter the new IP address After pressing 1 Type entry menu will be displayed at the bottom of the window T...

Страница 20: ...87 Connecting Converting Leading email info santelequip com 20 5 Press any key New IP address will be shown in the IP Address settings as below 6 For new IP to take effect it is necessary to restart t...

Страница 21: ...ntelequip com 21 7 Now restart the unit using Shift 1 key Following window will be displayed 8 Change the laptop IP address as compliant with new IP address of the gateway The gateway IP above was set...

Страница 22: ...r using the built in DHCP Client The network s DHCP Server must be setup correctly for this to work Please contact your network administrator for assistance i Enable the DHCP Client on Ethernet port N...

Страница 23: ...se to connect with Ruinet to the gateway i Enable the DHCP Server on Ethernet port N1 by pressing 5 ii Press Y Enter to enable N will disable the DHCP Server iii Press any key to continue and escape b...

Страница 24: ...E screen will indicate when the DHCP Server has been disabled Also subnet netmask DHCP settings and gateway settings can be changed in the above settings 4 16 Restart the gateway Push the Shift 1 key...

Страница 25: ...UI allows the user to 1 Check the status and diagnostics of a FieldServer including such information as network settings connection info node information map descriptors and error messages 2 Monitor a...

Страница 26: ...ing Leading email info santelequip com 26 5 2 Help It shows the information about the contents such as Configuration parameters Active profiles and available profiles 5 3 Network Setting Here we can s...

Страница 27: ...necting Converting Leading email info santelequip com 27 5 4 System Restart The gateway can be restart by using this button After pressing System Restart button press OK to restart take effect It will...

Страница 28: ...he gateway including the configuration code version memory gateway type and more Under Settings the user has access to important network information The name of the root is specified in the Gateways C...

Страница 29: ...date the Gateway s configuration file click the browse button and select the configuration file csv Click open and submit Wait until the message Configuration update complete appears and click the Sys...

Страница 30: ...d The N1 and N2 if supported adaptor IP address Netmask and default Gateway can be changed by entering values in the applicable fields and clicking on the Update IP settings Button NOTE The Gateway ha...

Страница 31: ...ned by 2 account names Admin or User The Admin account has unrestricted access to the Gateway The User account can view any Gateway information but cannot make any changes or restart the Gateway 6 4 V...

Страница 32: ...d by clicking on the Enabled Grid button and changing the value in the data array grid Note that if values are being written into the Array by a driver then any modifications made by grid editing will...

Страница 33: ...ng only 6 5 User Messages The user message screens display Gateway messages generated by drivers and the operating system User messages on the Error screen usually indicate some problem with the confi...

Страница 34: ...t 2 Open a web browser on PC and put IP address of BACnet router e g If gateway IP address is 192 168 1 200 put this IP into browser PC IP should be 192 168 1 X Web page settings will open as shown in...

Страница 35: ...P Ltd 504 505 Deron heights Opp Mahabaleshwar hotel Baner Road Baner Pune 411 045 Phone 020 65001587 Connecting Converting Leading email info santelequip com 35 7 1 BACnet Router GW BMS 02 02R Connec...

Страница 36: ...tocol e g BACnet IP Modbus TCP In order to establish communication with the SNMP servers configuration file needs to be downloaded in the gateway This configuration file will contain parameters like I...

Страница 37: ...unicate to the BACnet IP devices 9 CONNECTION DETAILS NAME DETAILS 24 V AC DC and E Connect 24 V AC DC supply Ethernet port BACnet IP Host field protocol support BACnet IP in GW BMS 01 GW BMS 02 GW BM...

Отзывы: