background image

 

 

27 

2.3 Auto Range 

Range can be adjusted manually or automatically. 

Automatic  adjustment  is  useful  when  you  are 

preoccupied with other tasks and do not have the time 

to adjust the display. 

 

 

 

 

 

 

 

 

 

 

 

2.4 Display speed 

The picture advance speed determines how quickly the 

vertical scan lines run across the screen. When choosing a 

picture advance speed, keep in mind that a fast advance 

speed will expand echoes horizontally on the screen and a 

slow advance speed will contract them. A fast advance 

speed is useful for observing the rugged bottom closely. A 

slow advance speed is useful for observing the smooth 

bottom

.

( Maximum speed X 8 , Minimum Speed X 1/8 

 

 

 

 

 

 

 

 Setting range 

[MENU]

 select [display] 

 select [auto range]

 

 

(select among 

off/auto range

   

 

 Setting for display speed 

[MENU]

 select [display] 

 select [display speed]

 

 select desired speed   

 

  28 

2.5 Interference   

Their  induced  noise  from  the  electric  apparatus  and  the  occurrence  of  periodic  interference 

from the lineup of a fish finder is the ability to eliminate noise. 

 

 

 

 

 

 

 

 

 

< Interference>                                                < noise reduction> 

 

 

 

 

 

 

 

 

 

2.6 Refresh area   

Change  from  the  current  value,  whether,  as  a 

whole should choose. 

 

 

 

 

 

 

 Setting for interference 

[MENU]

 select [display]   

 select [interference]

 

 select desired level 

 Setting for noise reduction 

[MENU]

 select [display] 

 select [noise reduction]

 

 

select among 

off/on

 

 Setting for refresh area 

[MENU]

 select [display] 

 select [refresh area]

 

 

(select among 

all/from now  

Содержание SDF-315

Страница 1: ...tion of display unit 11 3 Display functions 12 4 Component 13 3 Discription 14 1 Display discription 15 2 Power ON OFF 16 3 Menu 17 4 Display mode 19 4 Functions 20 1 SONAR 21 1 1 Tx Power 21 1 2 Tx R...

Страница 2: ...th Scale 39 4 6 help 39 4 7 Color Table 40 4 8 Temperature Graph 40 4 9 Detection Area 41 4 10 Header Info 41 4 11 Units 42 4 12 View Volt 42 4 13 Date Time 43 4 14 COG SOG 44 4 4 15 Lati Longi 44 5 A...

Страница 3: ...ble connection 57 3 Rear Connector Pinout 58 4 Power Cable Connection 59 6 Maintenance and Troubleshooting 60 1 Maintenance 61 2 Troubleshooting 62 Appendix Product outline drawing 63 6 This chapter e...

Страница 4: ...rfered by other equipment or affect to other Install at the place without direct sunlight to prevent drop of visibility and heating the equipment 8 2 Before handle cables Safety instruction 3 Before h...

Страница 5: ...in range of power 12 35VDC 3 Do not use solvent The main equipment is made by plastic and coated Do not use solvents like thinner or alcohol on it To remove dirt wipe with soft fabric soaked in water...

Страница 6: ...nment Temperature Main equipment 15 55 Humidity Less than 93 30 60 12 3 Functional specification Display Display color 8 16 64 Background selectable among 5 colors Range 5 3000m Shift 0 2000m Extensio...

Страница 7: ...V 7A 1EA 1EA 4 Spare fuse 24V 5A 12V 7A 3EA 3EA 5 DATA connector SCN 16 7P 1EA 6 Transducer connector SCK 25 8P 1EA When connect with own transducer of vessel 7 Installation accessory 1SET 8 Operation...

Страница 8: ...vailable in Auto shift Auto range mode 3 Menu ESC Open Close the menu Escape from current operation 4 Func Please read 6 3 Func key 5 Cursor Move in the menu list Set the level of adjustment Move VRM...

Страница 9: ...ust H 1 SONAR 11 Tx Fix 12 Bottom Search 13 Trigger Sweep 1 Direction 2 Division 3 A Scope 4 Depth Size 5 Depth Scale 6 Help 7 Color Table 8 Temp Graph 4 VIEW 9 Detection Area 10 Header Info 11 Units...

Страница 10: ...en button to select a desired screen mode Screen mode switch Low high frequency Low Frequency High Frequency Magnification Screen Low Frequency Magnification Screen High Frequency 20 This chapter expl...

Страница 11: ...If you set it ON then you can reduce your interference on other vessel 1 4 Pulse Width The pulse width is changing depending on range and Shift but it could be set by manually If you set short pulse...

Страница 12: ...order using the low frequency transmitter High frequency transmit and receive low frequency high frequency in order using the hig frequency transmitter OFF Use all low and high frequency transmitter...

Страница 13: ...NU Select Sonar Select Trigger Sweep Select ON OFF 26 2 Display 2 1 Mode It can set a screen display mode 2 2 Range Range value can be changed by shift key and range key Setting for Mode selection MEN...

Страница 14: ...the smooth bottom Maximum speed X 8 Minimum Speed X 1 8 Setting range MENU select display select auto range select among off auto range Setting for display speed MENU select display select display sp...

Страница 15: ...e Setting for high frequency TVG distance MENU select display select TVG distance high select desired distance 30 2 8 STC This is useful to clear the surface of unwanted echoes to look for surface fis...

Страница 16: ...lue Setting for auto gain offset of high frequency MENU select display auto gain offset H select desired value 32 3 Color 3 1 day night It can change the menu and background color of the screen When y...

Страница 17: ...erase Because this function removes unwanted low level echoes off the screen by cutting them off it is effective when the image is difficult to see because of interference or when you want to see only...

Страница 18: ...setting range is from 0 to 100 3 8 Color of white line It can change the color of white line color of white line without white line white line 100 Setting for white line MENU select color select whit...

Страница 19: ...division MENU select view select division select among vertical horizontal 38 4 3 A SCOPE A scope is the picture to show the strength of echo amplitude on the right side of the screen As A scope displ...

Страница 20: ...help MENU select view select help select among off on end 5 seconds 40 4 7 Color table It can select whether it will show the color table on the right in the center of screen or not Color Table on of...

Страница 21: ...ion MENU select view select header info Select among on off 42 4 11 Setting for unit Depth select depth unit temperature select temperature unit 4 12 View Volt Select voltage view on lower part of the...

Страница 22: ...is required 4 15 Lati Longi Select displaying GPS Lati Longi on upper left corner of the screen GPS connection is required displaying date time compass speed Lati Longi is on Select displaying date t...

Страница 23: ...larm select minimum Select among 3 3000 setting for maximum temperature MENU select alarm select maximum Select among 3 3000 Setting for fish school MENU select alarm select fish school Select among o...

Страница 24: ...1 Zoom mode Select your desired zooming mode as belows 7 2 Setting for zoom start Select the starting point for partial zoom 7 3 Setting for zoom end Select the ending point for partial zoom 7 4 Setti...

Страница 25: ...e screen is enlarged or when shifting is applied Only operating at the range of depth between 3m 100m Will not operate if the school of the fish is 3m or less It may display invalid value if transmit...

Страница 26: ...hoice 52 9 3 NMEA Input NMEA input port configuration 9 4 UART1 Among RS 232C port from the main unit it will transmit DPT to NMEA1 port and receive GPS data Speed can be set up with 4800 9600 or 3840...

Страница 27: ...ocal time configuration MENU NEMA input local time select time zone select Local time display configuration MENU NEMA input Time format select 24hours 12hours Date display configuration MENU NEMA inpu...

Страница 28: ...hanged depending on type of beam angle Setting for temp modification MENU select calib Select temp Select from 3 to 3 Setting for voltage modification MENU select calib select voltage select among 3 3...

Страница 29: ...racket mounting bolts display bracket mounting screw bracket mounting 58 2 Cable connection Connect power supply and transducer to the proper connector ETHER NET It will be updated later to use with S...

Страница 30: ...ALARM ALARM_GND TEMP1 TRANSDUCER_L TD_L NC TD_GND TD_L NC TEMP2 NC PWR EARTH PWR NAME2 SENSOR GND GND NMEA_IN NMEA_OUT SPEED SUPPLY SPEED TEMP GND SHIELD NC TRANSDUCER_H NC TD_H TD_GND NC TD_H NC NC...

Страница 31: ...Action Connector and terminal Please check the connector and terminal on the back of the display for proper connection Cable Check each cable and if the cable is damaged or blown replace it immediatel...

Страница 32: ...ange of screen color Contact of LCD connector Cleanness around LCD connector Fish school isn t display on the screen Poor contact of transducer connector and corrosion Transducer is under water Sensit...

Страница 33: ...65...