4st Edition of TEMI2000_Series IM : Aug. 18. 2009 Page 30 / 55
☞
Press
(Enter) button to complete time signal setting.
☞
Press
(ESC) button to cancel input and disappear Input Keypad.
※
Four TIME SIGNALs, TS1 to TS4 can be set among 18 types from [5.4 TIME SIGNAL] by pressing
TS1~TS4 button.
Table 5-1. PATTERN SET Parameters
Parameter
Range
Unit
Default
PATTERN NUMBER
1~120
ABS
1
START CODE
NOW PV, TEMP SP, HUMI SP
ABS
NOW PV
TEMP SP of Segment #n
T.EU(0.00~100.00%)
T.EU
T.EU(0.00%)
HUMI SP of Segment #n
H.EU(0.0~100.0%)
H.EU
H.EU(0.0%)
Process Time of Segment #n
-00.00.01(OFF) ~ 999.59.59(H.M.S)
ABS
-00.00.01
TIME SIGNAL 1 to 4 of
Segment #n
0 ~ 17
ABS
0
WAIT function of Segment #n
USE, UNUSE
ABS
UNUSE
* #n : 1 ~ 99