English
23
Installation
STEP 3
Connect the electrical wiring (for electric models)
Before connecting the electrical wiring, make sure you have read the “
3-wire system
A
B L2
L1
C
D (N)
E
A.
External ground connector
B.
Neutral grounding wire (white)
C.
Center silver-colored terminal block
screw
D.
Neutral wire (white or center wire)
E.
3/4” (1.9 cm) UL-listed strain relief
1.
Loosen or remove the center terminal
block.
2.
Connect the neutral wire (white or
center wire) of the power cable to the
center, silver-colored terminal screw of
the terminal block. Tighten the screws.
3.
Connect the other wires to outer
terminal block screws. Tighten the
screws.
4.
Tighten the strain relief screws.
5.
Insert the terminal block cover into the
rear panel of the dryer. Then, secure the
cover with a hold-down screw.
CAUTION
• To convert from the 4-wire system
to 3-wire system, connect the ground
strap to the terminal block support to
ground the dryer frame to the neutral
conductor.
• Ring-type terminals are recommended.
If using strap terminals, make sure they
are tightened.
• Connect the power cord and check L1/
L2/N voltage. If the voltage is low, It
may not dry properly.
Untitled-12 23
2019-12-12 12:21:54
Содержание DV50T5300C
Страница 1: ...Dryer User manual DVE G 50R5400 DVE G 50T5300 DVE G 50R5200 Untitled 12 1 2019 12 12 12 21 49...
Страница 61: ...Secadora Manual del usuario DVE G 50R5400 DVE G 50T5300 DVE G 50R5200 Untitled 13 1 2019 12 12 12 23 57...
Страница 121: ...Notas Untitled 13 61 2019 12 12 12 24 15...
Страница 122: ...Notas Untitled 13 62 2019 12 12 12 24 15...
Страница 123: ...Notas Untitled 13 63 2019 12 12 12 24 15...