PAGE 17of 46 HG-1-1701 GAS-FIRED HEATER
LAST UPDATED: JAN-25-2022 © SAMUEL JACKSON, INCORPORATED 2011 ALL RIGHTS RESERVED
HOW DO I SET THE TEMPERATURE?
The set point (SP) for the air temperature is set by touching the Target box on the Home screen
and using the keypad to input the desired temperature. Changing the SP can be done with the
heater on or off. The range that the set point can be adjusted depending upon the minimum and
maximum set point settings that have been made in the Setup Screen under Temp Limits.
WHERE DO I INSTALL THE AIR TEMPERATURE
THERMOCOUPLE?
A thermocouple with blue paint on the pipe threads (Part No. 21708) is supplied for
installation in the hot air duct after the heater. Place it
at least
10 feet away from the
outlet of the heater. If the heater is part of a Samuel Jackson Super Grid System or a
Samuel Jackson Steamroller System, more detailed information will be supplied to you
specifically for your system. See
THERMOCOUPLE WIRING
section for more details.
AIR SETPOINT
(SP)
10 FEET
minimum