MP9311 User’s Guide
20
8. Set
Digital input 0 (DIN0) gates auto read action
to
Enable
.
9. Finally, set the duration of the output pulse. On the
Reader Config
interface tab,
select:
Reader Configuration
D
General Configuration
D
Operating Mode
D
Protocol Digital I/O Control
10. Enter a value in milliseconds.
11. Press
Send Changes to Reader
to reconfigure the reader with the news settings.
Connecting the External Trigger Circuit
12. As shown in Figure 14, apply +5 Vdc to DIN0+ (Pin 8) on SCON1.
13. To trigger a read, pull DIN0- (pin 5) Low (0 Vdc or ground) for at least 50
milliseconds.
Figure 14–Typical Digital Input Trigger Circuit
14. When a tag is singulated, DOUT0 goes high for the duration set by the PIO register.
NOTE: When a tag is read, DOUT0 is asserted and stays asserted as long as tag activity
continues. The pulse duration calculation is reset with each valid read. Therefore, if the
pulse is still in process and a read operation is performed, the pulse will be extended by
the value contained in PIO. This logic guarantees a pulse of a specific duration since the
last read that occurred
+5 Vdc
External Trigger
(hold for 50 mSec)
4.7K
+5 Vdc
DIN0-
DIN0+
DOUT0
1
2
19
20
Содержание MP9311 Series
Страница 1: ...User s Guide MP9311 Low Power UHF Reader Module THE POWER TO CHOOSE...
Страница 6: ...MP9311 User s Guide iv...
Страница 12: ...MP9311 User s Guide 6...
Страница 34: ...MP9311 User s Guide 26...
Страница 58: ...MP9311 User s Guide 50...
Страница 59: ......
Страница 60: ...SAMSys Technologies Inc Part Number MP9311 01 UG V1 0 Printed in U S A THE HE P POWER OWER T TO C CHOOSE HOOSE...