12 _ Removal and Reassembly
Part
Figure
Description
Separating the
Cover_Top and
Panel-Control
(Check Main-PCB
and Sub-PCB)
1. Remove the 2 hexagon screws, which are at the
back, fixing the COVER-TOP.
2. Disassemble the COVER-TOP by sliding it
backwards and remove the 4 screws on the
PANEL-CONTROL.
3. With the top cover removed you will now have
access to service the Water pressure sensor, EMI
Noise Filter, Hot and Cold Water Valves, Steam
ASSY, Hose Draw ASSY, And main PCB ASSY.
4. Press the Separate button to separate the ASSY
Drawer.
5. Disassemble the HOUSING-DRAWER frome the
PANEL-CONTROL (push back and then push
Housing-drawer upside to separate).