Samsung WF338 XAA Series Скачать руководство пользователя страница 5

Error Type  

Error Mode  

Details  

LED LCD 

                             
Drain Error 

                         
nD                               

 

Check for Foreign material entering the pump or hoses.  

Check to make sure the wiring harness is connected properly. 

Check the water pump terminal . 

Check for freezing 

                         
Power Error  

                         
2E           
91           
92  

 

Make sure to check the operating voltage. (An error occurs when 
under or over voltage is supplied.)   Check whether a plug recepta-
cle is used. When the connecting wires are too small (extension 
cord use), a momentary low voltage may drop up to 10 V 

Main PBA fault (sometimes) 

PF 

 

Momentary Power Failure 

                                 
Communica-
tion Error 

AE 

 

Check the wire connections and terminal contacts between the sub 
and main PBAs. 

Check for disconnected wires. 

Check whether the sub PCB is short circuited because of moisture. 
If the main PCB’s communication circuit is faulty, replace it. 

                              
Switch Error 

(Main Relay 

Error)  

                         
E2           
15 

 

Check whether either the Power switch or a tact switch (any button)  
is stuck down. 

Check whether the service PBA holding screws are fastened too 
tight pinching the contacts 

If the main PBA switching IC on/off error has occurred, replace the 
main PBA. 

The “E2” error occurs if the main relay connections are incorrect. 
Check the connections. If there is no error in the connections, re-
place the main PBA  

                        
SR 

 

 

dS           
22 

(Before 

operation) 

 

Door Error 

dL           
18 

(During 

operation) 

 

 

LO            

(Unlock 

Fail) 

 

 

FL             

(Lock Fail) 

 

 

 

 

Check the door switch and latch alignment .  

Check the latch for damage 

Check the wiring harness to the latch.  

Check the door switch. Replace if faulty. 

Check the main PBA door sensing circuit. Replace if faulty. 

Finally verify he operation of the Main PCB 

EEPROM 
Fault. 

11 

 

Go to “EEPROM Clear Mode” If display shows “FAiL”, Replace Ma-
chine Control Board 

 

5

Содержание WF338 XAA Series

Страница 1: ...tton to see how many times the unit was used Soft Ware Press the Soil button to see the software version information Fast Time Down Press the Temp button to advance to the next cycle Fault Code Test Press the Silver Care button to view the stored fault codes then turn Jog Dial to view error codes Push Start Pause while the code is displayed to view the num ber of cycles since the error occurred Pe...

Страница 2: ...WF338AA Gray Gray CN1 2 ...

Страница 3: ...Test 2 Connector CN 7 Pin 4 Yellow and CN7 Pin 5 Orange Operating voltage at Room temperature Operating Resistance at Room Temperature Power off discon nect CN7 4 2VDC 5VDC May indicate a connector issue 50 57kΩ Door Switch Check Test 1 Test 2 Connector CN4 Pin 1 Pink and CN4 Pin 3 Gray 25VDC Door Open 0VDC Door Closed Operating Resistance with power off 24kΩ Water Level Sensor Check Test 1 Test 2...

Страница 4: ...6 Ω Steam Heater Relay Check Test 1 Test 2 Connector CN2 Pin 3 Brown and RY4 heater relay Pin 1 Black 120VAC with the Heater On and 0VAC with the Heater off Power Off heater resistance is 15 6 Ω Error Type Error Mode Details LED LCD Water Level Sensor LE 8 Check the Hose where the sensor is connected may be loose pinched damaged or clogged Also check the sensor it may be disconnected or defective ...

Страница 5: ...e If the main PCB s communication circuit is faulty replace it Switch Error Main Relay Error E2 15 Check whether either the Power switch or a tact switch any button is stuck down Check whether the service PBA holding screws are fastened too tight pinching the contacts If the main PBA switching IC on off error has occurred replace the main PBA The E2 error occurs if the main relay connections are i...

Страница 6: ...y the water valves shut off fully Finally check the water level sensor Temperature Sensor Error 29 The washing heater temperature sensor in the tub has an error Check the connections for the washing heater temperature sensor connector Unbalance Error dC 10 Check the type of laundry Check whether it may cause an unbal anced situation Educate the consumer in this case to press pause reposition the l...

Страница 7: ...chase from your Samsung retailer Location considerations Do not install your washer in areas where water may freeze since your washer will always maintain some water in its water valve pump and hose areas This can cause damage the belts the pump hoses and other components Operat ing temperature should be above 60 F 16 C Selecting Language 1 The Select the Language message appears 2 Turn the Jog Di...