14-6
14. REFERENCE INFORMATION
No.
Type
Part
Situation
Solut ion
method
Before consu lting
cause
Management
18
DRUM
WASHER
water leakage
related
water being leaked at water supply
connection part
General
consulting
It may be occurred when it is pushed out due to
the water pressure or it has bad connection.
f
Disconnect the coupler and reassemble it. It had better to
assemble by yourself because the engineer’s visit for service will be
additionally charged in case of dif
fi
cut installation by customer.
19
DRUM
WASHER
water leakage
related
Water leakage being occurred during
water supply
General
consulting
The leakage during water supply can occur
possibly due to the bad connection of tap and
coupler and water supply hose.
)
First re-assemble the coupler and then check by the engineer if it
continues.
20
DRUM
WASHER
water leakage
related
Natural drain(continually)/water not
fi
lling tub
General
consulting
It can be appeared at the drum washing machine
of which the drain hose is located at the bottom.
f
For the machine having the drain hose at the below of that raise
the drain hose up and
fi
x it to the
fi
xer at 2/3 point of the machine. If
the hose is used at the
fl
oor all water supplied will drain fully.
21
DRUM
WASHER
smell/smoke
Burning smell
General
consulting
For the initial use of product It may appear during
the operaiton with coupling each other but it
carefully watched by the customers who are
using more than for 3 years.
f
Is that a newly bought one?
)
A smell is disappeared after 4~5 days passed in case of newly
bought one but it depends upon the frequency of use. Be sure to use
it without worry. If is not disappeared contact a engineer
22
DRUM
WASHER
smell/smoke
Burning/smoke
General
consulting
Pull out the plug in case of smoke or
fi
re.
It can be shown in case that the interior
components of the products do not work
normally.
)
In this case you are recommended our engineer’s inspection.
23
DRUM
WASHER
power soruce
related
Power not supplied
AS rerecomm
ended
It can be shown in case that the power cord is
not inserted or electricity is blacked out or the
interior components of the products do not work
properly.
)
Take out the power cord and put it in again and check whether the
power for the other products is on. If it is not even after that you are
recommended our engineer’s inspection.
24
DRUM
WASHER
power soruce
related
Current leakage breaker being
dropped
General
consulting
It may be occurred when the humidity is full
inside the machine.
)
In this case you are recommended our engineer’s inspection.
25
DRUM
WASHER
power soruce
related
Autmatic stop during operation
AS rerecomm
ended
It may be occurred when there are too much
laundry.
f
Reduce the contents to be washed. If it continues you are
recommended our engineer’s inspection.
26
DRUM
WASHER
power soruce
related
Being power off frequently
AS rerecomm
ended
It may be occurred in case of the bad contact of
button.
)
In this case you are recommended our engineer’s inspection.
27
DRUM
WASHER
operation related
Button being not operated
Consulting
It may be occurred when the accumualtion of
foreign material or moisture ingress into the
button.
)
In this case you are recommended our engineer’s inspection.
28
DRUM
WASHER
operation related
Being not rotating during washing
AS rerecomm
ended
It may be occurred when the water supply not
completed or the cover not closed completely or
the accessories of products have a abnormallity.
)
First check whether the tap is open and the cover closed and then
request an engineer’s inspection.
29
DRUM
WASHER
4E :front loading
washing machine
error
Water level sensor inferiority
AS rerecomm
ended
This may be happened when there is any
foreign material inside the water supply and drain
valve or the interior components of the prodcuts
do not operate normally. Water level sensor or
mother rotation.
)
Disconnect the water supply hose and check whether there is
a foreign material inserted in it. And then request an engineer’s
inspection.
30
DRUM
WASHER
5E :front loading
washing machine
error
Water being not drained
AS rerecomm
ended
It may be occurred when the drain hose is go
over the threshold or water is not drained.
It may eb occurred when the The
fi
lter of
pumpdrain moder is fulled with dregs,
Check the installation of drain hose and then if there is no trouble
request an engineer’s inspection.
Clean the
fi
lter of pump-drain motor. Guided by instruction-manual.
31
DRUM
WASHER
OE :front loading
washing machine
error
3E OVER-FLOW
General
consulting
It may be a case that the supply water level is not
detected.
)
After Draining the water power off and on and operate again. If it
dose not work after so doing request an engineer’s inspection.
32
DRUM
WASHER
UE :front loading
washing machine
error
4E UNBALANCE ERR
General
consulting
It may be happened when the
fl
oor of the
installed palce is not
fl
at or the clothes are
entangled.
Level the machine or arrange the entangled clothes. If it does not
worked even after so doing request an engineer’s inspection.
33
DRUM
WASHER
HE1 : front
loading washing
machine error
E5 WATER HEATER ERR
General
consulting
It may happen when the boiling temperatuer
rised rapidly. (It is also because too much
detergent are used.)
Use the proper amount of detergent and power off the machine till the
temperaure is cooled down.
And if it does not work even after so doing request an engineer’s
inspection.
34
DRUM
WASHER
HE : front loading
washing machine
error
E6 WATER HEATER ERR
AS rerecomm
ended
It may appear when it dose not reach to the set
temperature within a certain time.
)
In this case you are recommended our engineer’s inspection.
Содержание WF-F125AV
Страница 1: ...9 1 9 BLOCK DIAGRAM ...
Страница 2: ...9 2 9 BLOCK DIAGRAM Memo ...
Страница 6: ...13 1 13 CIRCUIT DESCRIPTIONS 13 1 OVERALL SYSTEM DIAGRAM ...
Страница 23: ...7 3 7 EXPLODED VIEWS AND PARTS LIST Memo ...
Страница 28: ...7 8 7 EXPLODED VIEWS AND PARTS LIST Memo ...
Страница 64: ...10 SCHEMATIC DIAGRAM 10 1 10 SCHEMATIC DIAGRAM 10 1 EMZ NOT USE IN THIS MODEL ...
Страница 65: ...10 SCHEMATIC DIAGRAM 10 2 10 2 ROLD WF7452S9R C WF7450S9C ...
Страница 74: ...10 SCHEMATIC DIAGRAM 10 1 10 SCHEMATIC DIAGRAM 10 1 EMZ NOT USE IN THIS MODEL ...
Страница 75: ...10 SCHEMATIC DIAGRAM 10 2 10 2 ROLD WF7452S9R C WF7450S9C ...
Страница 78: ...7 3 7 EXPLODED VIEWS AND PARTS LIST Memo ...
Страница 83: ...7 8 7 EXPLODED VIEWS AND PARTS LIST Memo ...