5-8
Troubleshooting
5-3-10 (N) Check of instantaneous over-current protection of IPM circuit.
Inverter instantaneous over- c u r rent protection mode is the mode to be actuated in order to
p revent the damage of elements from the peak current of IPM circuit elements.
In case that the inverter circuit instantaneous over- c u r rent protection mode actuates.
(condition of installation)
♦
The ventilation is not good because the outdoor unit is installed wrong (the ambient tempera-
t u re is higher than 50 (°C) )
-> Reinstall the outdoor unit so that the good ventilation can be made.
♦
In case that the operation is made with the cover bent of the outdoor unit.
-> Take out the cover.
♦
If two outdoor units are operating face to face, (the bad ventilation is made)
-> Reinstall the outdoor unit for the good ventilation.
♦
The air circulation is bad due to the attachment of falling leaves.
-> Take away the leaves for the good ventilation.
♦
If the Refrigerant is overc h a rged.
-> Check the amount of Refrigerant.
(Unit defect)
♦
If the comp is locked.
-> Replace the comp.
♦
If the comp is operating without the revolution of fan motor.
-> Check the fan motor connector and replace the fan motor.
♦
In case the parts of the control board is damaged.
-> Replace simultaneously the inverter control board and the IPM board .
5-3-11 (O) Check of the comp discharge gas temperature and OLP temperature abnormal rise.
If the comp discharge gas temperature and OLP t e m p e r a t u re rises higher than a certain level, it
p rotects the circ u i t .
If the comp discharge gas temperature and OLP t e m p e r a t u re rises abnormally,
(Condition of installation)
♦
The ventilation is not good because the outdoor unit is installed wrong (the ambient tempera-
t u re is higher than 50 (°C) )
-> Reinstall the outdoor unit so that the good ventilation can be made.
♦
In case that the operation is made with the cover bent of the outdoor unit.
-> Take out the cover.
♦
If two outdoor units are operating face to face, (the bad ventilation is made)
-> Reinstall the outdoor unit for the good ventilation.
♦
The air circulation is bad due to the attachment of falling leaves
-> Take away the leaves for the good ventilation.
♦
If the refrigerant is insufficient.
-> Fill up the amount of re f r i g e r a n t .
Samsung Electronics
Содержание UQV09A1ME
Страница 3: ...1 2 MEMO Samsung Electronics ...
Страница 32: ...MEMO 5 13 Samsung Electronics MC Service ...
Страница 33: ...6 1 6 Exploded Views and Parts List 6 1 Indoor Unit Samsung Electronics ...
Страница 35: ...6 3 6 2 Outdoor Unit Samsung Electronics ...
Страница 41: ...7 1 7 PCB Diagrams 7 1 ASS Y PCB IN DB93 00323A TOP BOTTOM Samsung Electronics MC Service ...
Страница 43: ...7 3 7 2 ASS Y PCB Control Out DB93 00324A TOP Samsung Electronics MC Service ...
Страница 44: ...7 4 PCB Diagrams BOTTOM Samsung Electronics ...
Страница 46: ...PCB Diagrams 7 6 7 3 ASS Y PCB IPM DB93 00353A TOP BOTTOM Samsung Electronics ...
Страница 50: ...8 1 8 Wiring Diagrams 8 1 Indoor Unit Samsung Electronics ...
Страница 51: ...8 2 8 2 Outdoor Unit Samsung Electronics MC Service ...