12-6
Samsung Electronics
Troubleshooting
12-2-5 In case of heating at the cooling mode or cooling at the heating mode
1. Troubleshooting procedure
Change the setting temperature of
remote control.
Operate it with a heating mode
as soon as the defrosting is finished.
After 3 minutes, cooling
and heating start automatically.
No
No
No
Yes
Yes
Yes
Is the Thermo off?
Is the unit
in the defrosting operation?
Is the compressor
in 3 minutes off?
Check the resistance value
of 4-WAY valve coil.
Go to the next page
4-WAY valve main body error
Attach the
sensor correctly.
Over shortage
of the refrigerant
Connect the connecter
correctly.
4-WAY valve coil error
Exchange
the outdoor PCB.
No
Yes
Yes
Yes
OK
Yes
No
No
No
NG
No
Is much frost
in the indoor heat
exchanger?
Does the
4-WAY valve operate
normally?
Is the
outdoor air sensor and
outdoor heat exchanger attached
correctly?
Is the
4-WAY valve connector
connected correctly?
Dose the
voltage of AC 220V
apply to the connector of 4-WAY
valve coil during the
operation?
26006A(2)_2.indd 6
2006-04-14 ソタネト 5:16:10
Содержание UQB09JJWC
Страница 28: ...Samsung Electronics MEMO 4 8 26006A 2 _1 indd 17 2006 04 14 ソタネト 5 12 59 ...
Страница 34: ...Samsung Electronics MEMO 5 6 26006A 2 _1 indd 23 2006 04 14 ソタネト 5 13 22 ...
Страница 56: ...Samsung Electronics MEMO 8 4 26006A 2 _1 indd 45 2006 04 14 ソタネト 5 13 39 ...
Страница 60: ...Samsung Electronics 9 2 Refrigerating Cycle Diagram 9 4 26006A 2 _1 indd 52 2006 04 14 ソタネト 5 13 53 ...
Страница 105: ...Samsung Electronics MEMO 14 11 26006A 2 _2 indd 37 2006 04 14 ソタネト 5 16 23 ...
Страница 106: ...Samsung Electronics MEMO 14 12 26006A 2 _2 indd 38 2006 04 14 ソタネト 5 16 23 ...