3-6
3. Disassembly and Reassemble
Description & Screws
Picture Description
9
Before remove ASSY PCB MAIN,
Discharge Capacitors
1CNT
Before remove 3in1 board, Must discharge
capacitors for your safety.
Check discharge point(1st, 2nd block) and then,
discharge with discharge-Jig.
Service Jig-Capacitor Discharge
•
If
LED ON
£
LED OFF
discharge is
completed.
BN81-16292A
<Before discharging> <After discharging>
LED ON
LED OFF
9
Then verify voltage is less than 10Vdc across
leads with Volt Meter.
Measurement point
Measurement point