4-4. White Balance
4-4-1. MGA(Multipoint Grayscale Adjustment)
MGA(Multipoint Grayscale Adjustment)
DEVICES
Type
CA-210
32A6AF0VJ
RGB Measurement
Levels
Code
Check
10 IRE
0x01
O
20 IRE
0x02
O
30 IRE
0x03
X
40 IRE
0x04
O
50 IRE
0x05
X
60 IRE
0x06
X
70 IRE
0x07
O
80 IRE
0x08
X
90 IRE
0x09
X
100 IRE
0x0A
O
Panel Inspection Spec.
Levels
Check
x(±)
y(±)
Gamma(±)
10 IRE
O
0.020
0.020
0.40
20 IRE
O
0.020
0.020
0.40
30 IRE
O
0.020
0.020
0.40
40 IRE
O
0.020
0.020
0.40
50 IRE
O
0.020
0.020
0.40
60 IRE
O
0.020
0.020
NA
70 IRE
O
0.020
0.020
NA
80 IRE
O
0.020
0.020
NA
90 IRE
O
0.020
0.020
NA
100 IRE
O
NA
NA
NA
Gray Check
Adjust Spec(xyL)
Adjust Target offset(xyL)
Levels
Code
Check
x(±)
y(±)
L(±)
x(±)
y(±)
L(±)
10 IRE
0x01
X
0.007
0.007
0.11
0.000
0.000
0.000
20 IRE
0x02
O
0.007
0.007
0.08
0.000
0.000
0.000
30 IRE
0x03
X
0.007
0.007
0.06
0.000
0.000
0.000
40 IRE
0x04
O
0.005
0.005
0.05
0.000
0.000
0.000
50 IRE
0x05
X
0.005
0.005
0.04
0.000
0.000
0.000
60 IRE
0x06
X
0.005
0.005
0.03
0.000
0.000
0.000
70 IRE
0x07
O
0.004
0.004
0.02
0.000
0.000
0.000
80 IRE
0x08
X
0.004
0.004
0.01
0.000
0.000
0.000
90 IRE
0x09
X
0.004
0.004
0.01
0.000
0.000
0.000
100 IRE
0x0A
X
NA
NA
NA
NA
NA
NA
4-21