No picture (COMPONENT)
Diagnostics
If the LED of POWER is off,
check Back Light is turn on
No
Check what is status ‘Stand-by’ or not
Yes
Check a video source & cable
No
Check Video signal
Yes
Check the SelfTest.
(Support
Self Diagnosis
Picture Test)
Remain other Problem
No
Check for connecting external device
Yes
Check
R426(COMP1_Y/CVBS)
R424(COMP1_PR)
R425(COMP1_PB)
No
Check the CN403
Change the Main Assy
Yes
Check the assembling state of LVDS /
Change the Panel
4-6