4-2. How to Check Fault Symptom
NO Power and No Video
¢
Symptom
The LEDs on The front panel do not work when connecting The power cord.
•
The SMPS relay does not work when connecting The power cord.
•
The units appears to be dead.
•
Major
checkpoints
The IP relay or the LEDs on the front panel does not work when connecting the power cord if the cables are
improperly connected or the Main Board or SMPS is not functioning. In this case, check the following:
Check the internal cable connection status inside the unit.
•
Check the fuses of each part.
•
Check the output voltage of SMPS.
•
Replace the Main Board.
•
Diagnostics
Power cord on.
Yes
Check ‘Stand-By A5.3V’ 5.3V appear at
BD210?
5.3V (CN201 #4)
No
Cause
: There did not supply the
power from SMPS.
Measure
: Change 14p power cable
and SMPS.
Yes
Set On.
Yes
Check ‘SW_POWER’ more than 3.3V
appear at CN201(#2) ?
3.3V↑ (CN201 #2)
No
Cause
: Main IC(X13N) did not control
the SW_Power.
Measure
: Change the Main Assy.
Yes
Check ‘Power input of Main Ass’y’ ?
DC B13V, B5.3V appear at
CN201 #11,12,13(B13V)
CN201 #1,3 (B5.3V)?
13V (CN201 #11,12,13)
5.3V (CN201 #1,3)
No
Cause
: There did not supply the
power from SMPS.
Measure
: Change 14p power cable
and SMPS.
Yes
Check ‘Power of main IC(B1.15V)’.
Check ‘Power of DDR IC(B1.5V)’ appear
at B1.15V(L202), B1.5V(R214).
No
Cause
: There is proble at
DCDC(IC203) / LDO(IC204).
Measure
: Change the Main Assy.
Yes
Check ‘Power of LVDS (13V)’ appear at
TP-PANEL_VCC?
13V (TP-PANEL_VCC)
No
Cause
: There is proble at
FET(Q201_60) or Main
IC(X13N) did not control the
SW_PVCC.
Measure
: Change the Main Assy.
4-5
4. Troubleshooting
Содержание UN32F50**AF
Страница 25: ...2 17 2 Product speci cations Model UF4B UE32F40 AF UE4J UN EH40 0F Antenna 1 Cable Air 1 Cable Air...
Страница 39: ...Power Tree 4 3 4 Troubleshooting...
Страница 40: ...Power Tree 4 4 4 Troubleshooting...
Страница 108: ...5 2 5 Wiring Diagram U86A_HD Main Board Power Board T CON Speaker FUNCTION IR Speaker CN201 CN1302_HD CN302 CN702 CN1...