background image

31

Samsung Electronics

Set Up the Model Option

7

8

9

10

11

12

7

8

Press          button, then the default value is       .

Push the          button to set the display panel to 

.

Every time you push the button, the display panel reads 

. . .

repeatedly.

Setting is not required if you must 

a value which has a 

default.

9

Push the          button to set the display panel to 

.

Every time you push the button, the display panel reads 

. . .

repeatedly.

10

Push the          button to set the display panel to 

.

Every time you push the button, the display panel reads 

. . .

repeatedly.

11

Push the          button to set the display panel to 

.

Every time you push the button, the display panel reads 

. . .

repeatedly.

12

Push the          button to set the display panel to 

.

Every time you push the button, the display panel reads 

. . .

repeatedly.

Step 3 : Upon completion of the selection, check you made right selections.

Press the Mode Selection key,

to set the display part to 

and check the display part.

The display part shows

.

Press the Mode Selection key,

to set the display part to 

and check the display part.

The display part shows

.

Step 4 : Pressing the ON/OFF button (

)

When pressing the operation ON/OFF key with the direction of remote control for unit, the sound ''Ding'' or ''Diriring'' is

heard and the OPERATION ICON(

) lamp of the display is flickering at the same time, then the input of option is com-

pleted. (If the diriring sound isn't heard, try again pressing the ON/OFF button.)

Step 5 : Unit operation test-run

First,

Remove the battery from the remote control.

Second,

Re-insert the battery into the remote control.

Third,

Press ON/OFF button(

) with the direction of remote control for set.

• Error Mode

1

st

If all lamps of indoor unit are flickering, Plug out, plug in power plug again and press ON/OFF key to retry.

2

nd

If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the correct option code is

set up for its model.

 22143A(4)_1  2/13/06 3:03 PM  Page 31

Содержание UH052EZMC

Страница 1: ... Set Up the Model Option 5 Control Specification Troubleshooting 6 Exploded Views and Parts List 7 Block Diagram 8 Wiring Diagram 9 Schematic Diagram INDOOR UNIT DH052EZM1 DH070EZM LH105EZM1 HH105EZM1 LH128EZM1 HH128EZM1 LH140EZM1 HH140EZM1 OUTDOOR UNIT UH052EZMC UH070EZMC UH105GZMC UH128GZMC UH140GZMC SYSTEM AIR CONDITIONER ...

Страница 2: ...0 47 800 54 600 7 700 11 200 14 000 16 000 1 220 240 50 3 380 415 50 2 430 4 050 5 050 5 050 2 430 3 750 5 450 5 450 12 0 7 1 8 6 8 6 12 0 6 7 9 2 9 4 1 050 1 080 1 070 1 070 950 950 1 020 1 020 900 850 970 970 850 750 920 920 19 5 37 46 38 71 38 71 17 5 32 24 37 82 37 82 16 5 26 61 36 38 36 38 15 5 22 83 34 77 34 77 43 47 48 48 41 45 46 46 D Fin Wave 2 x 10 x 1 7mm 3 x 14 x 1 7mm Sirocco 97 112 2...

Страница 3: ... inch Connection Method Between Height m Pipe Length m R22 2 100 2 400 4 150 4 150 30 45 50 50 Elec Expansion Valve Wave 2 x 24 x 1 5 2 x 36 x 1 7 2 x 44 x 1 7 2 x 44 x 1 7 638 931 1 128 1 128 880 880 932 932 310 320 375 375 67 72 88 93 105 120 105 120 9 52 3 8 9 52 3 8 15 88 5 8 19 05 3 4 Flare Max 15 Max 30 Max 30 Max 50 Outdoor Unit Piping DH052EZM1 DH070EZM UH052EZMC UH070EZMC HH105EZM1 UH105G...

Страница 4: ...DOOR UNIT OUTDOOR UNIT 34 000 43 700 47 800 10 000 12 800 14 000 38 200 47 800 54 600 11 200 14 000 16 000 3 380 415 50 3 850 4 900 4 900 3 600 5 400 5 400 6 75 8 4 8 4 6 40 9 1 9 1 790 900 950 900 950 720 850 900 850 900 650 800 850 800 850 580 750 800 750 800 32 8 42 37 42 37 29 4 36 69 36 69 26 78 34 71 34 71 24 38 32 62 32 62 39 40 40 7 38 38 Wave 3 x 14 x 1 7mm Sirocco 112 2 211 211 390 390 3...

Страница 5: ...ize Liquid mm inch Gas mm inch Connection Method Between Height m Pipe Length m MODEL INDOOR UNIT OUTDOOR UNIT R22 2 400 4 150 4 150 45 50 50 Elec Expansion Valve Wave 2 x 36 x 1 7 2 x 44 x 1 7 2 x 44 x 1 7 931 1 128 1 128 880 932 932 320 375 375 88 93 105 120 105 120 9 52 3 8 19 05 3 4 Flare Max 30 Max 50 Outdoor Unit Piping LH105EZM1 UH105GZMC LH128EZM1 UH128GZMC LH140EZM1 UH140GZMC ...

Страница 6: ...otection MODEL INDOOR UNIT OUTDOOR UNIT 34 000 43 700 46 000 10 000 12 800 13 500 38 200 47 800 54 600 11 200 14 000 16 000 3 380 415 50 4 050 5 300 5 300 3 750 5 850 5 850 7 1 8 6 8 6 6 7 9 4 9 4 1 080 1 070 1 070 950 1 020 1 020 850 970 970 750 920 920 37 46 38 71 38 71 32 24 37 82 37 82 26 61 36 38 36 38 22 83 34 77 34 77 47 48 48 45 46 46 Wave 3 x 14 x 1 7mm Sirocco 112 2 211 211 390 390 390 1...

Страница 7: ...s W mm D mm Weight Net Gross kg Pipe O D Size Liquid mm inch Gas mm inch Connection Method Between Height m Pipe Length m R22 2 400 4 150 4 150 45 50 50 Elec Expansion Valve Wave 2 x 36 x 1 7 2 x 44 x 1 7 2 x 44 x 1 7 931 1 128 1 128 880 932 932 320 375 375 88 93 105 120 105 120 9 52 3 8 19 05 3 4 Flare Max 30 Max 50 Outdoor Unit Piping HH105EZM1 UH105GZMC HH128EZM1 UH128GZMC HH140EZM1 UH140GZMC ...

Страница 8: ...7 Samsung Electronics Unit mm 1 2 Dimensions 1 2 1 Indoor Unit No 1 2 Name Liquid pipe connection Gas pipe connection Remark ø9 52 Flare ø15 88 Flare DH052EZM1 DH070EZM ...

Страница 9: ...28EZM1 LH140EZM1 No 1 2 3 4 5 6 7 8 Name Liquid pipe connection Gas pipe connection Drain pipe connection Drain pipe connection Power supply connection Air discharge flange Air suction flange Hook Remark ø9 52 Flare ø19 05 Flare OD27 2 ID21 6 without drain pump OD29 ID25 with drain pump For M8 M10 ...

Страница 10: ...Product Specifications 9 Samsung Electronics 1 2 2 Outdoor Unit UH052EZMC UH070EZMC Unit mm 645 340 880 320 364 931 950 769 839 4 12 UH105GZMC Unit mm 310 638 660 880 ...

Страница 11: ...Product Specifications Samsung Electronics 10 690 932 375 1 128 1 162 966 403 427 1 036 4 12 UH128GZMC UH140GZMC Unit mm ...

Страница 12: ... kgf cm 2 G High Pressure kgf cm 2 G Low Pressure kgf cm 2 G High Pressure kgf cm 2 G Outdoor Temperature High Pressure kgf cm 2 G Outdoor Temperature Outdoor Temperature Outdoor Temperature Outdoor Temperature Outdoor Temperature UH052EZMC DH052EZM1 Cooling Mode UH070EZMC DH070EZM UH052EZMC DH052EZM1 Heating Mode UH070EZMC DH070EZM UH105GZMC LH105EZM1 Cooling Mode UH105GZMC LH105EZM1 Heating Mode...

Страница 13: ...ure kgf cm 2 G Outdoor Temperature Low Pressure kgf cm 2 G Outdoor Temperature High Pressure kgf cm 2 G Outdoor Temperature High Pressure kgf cm 2 G Outdoor Temperature UH128GZMC LH128EZM1 Cooling Mode UH140GZMC LH140EZM1 UH128GZMC LH128EZM1 Heating Mode UH140GZMC LH140EZM1 UH128GZMC HH128EZM1 Cooling Mode UH140GZMC HH140EZM1 UH128GZMC HH128EZM1 Heating Mode UH140GZMC HH140EZM1 ...

Страница 14: ... of indication part and then assemble the direction of 2 Plate Handle places by use of screw as shown in 2 2 Turn the Plate Handle by hand when removing the Filter Pre 3 When pulling the Filter Pre handle the Filter Pre can be assembled Be sure to remove the cushion on the marked part after initial installation It cause the damage of noise 1 After disassembling 9 places indicating screws detach As...

Страница 15: ...s Procedure Remark 2 Disassemble 6 indicating screws 3 Detach the Sensor Holder from the Ass y Fan Case 4 Detach from Ass y Control In the capacitor connection wire between the Motor Fan in and housing Connector 5 Detach the Ass y Blower and Duct from the set ...

Страница 16: ... 1 After disassembling 1 indicating screw detach the Cover Control 2 Detach the Motor Fan in and Sensor Connector connected to PCB 3 Disassemble 2 indicating screws arrow mark 4 Hold the Ass y Control In by hand to lift up a little and then release the status of hanging on the hanging slot ...

Страница 17: ... to detach Ass y Drain Pan 2 screws each at left and right side Work is possible when disassembling the Ass y Drain Pan 1 Disassemble 8 indicating screws 4 each at left and right side 2 Disassemble 6 indicating screws 3 Disassemble 5 indicating screws It is possible at the status of No 3 Ass y Control In disassembly at the time ...

Страница 18: ...ectronics No Parts Procedure Remark 4 After disassembling 4 indicating screws 5 Pull the Cabinet Side LF RH by hand to disassemble 6 Separate 4 indicating screws 2 each at left and right side 7 Detach it from the set if the Ass y Evap pull up ...

Страница 19: ...connecting canvas to the discharge side 1 Disassemble 4 indicating screws 2 each at left and right side 2 Disassemble 12 indicating screws 6 each at upper and lower side After connecting canvas to the disassembled Ass y Holder Outlet 2 attach the Ass y Holder Outlet to the set in the reverse order ...

Страница 20: ...from Ass y Control In 2 Detach the capacitor connection wire the Motor Fan in and housing connector from Ass y Control In 3 Disassemble 2 screws of indicating parts then lift up Ass y Control In 4 Disassemble 6 screws around indicating part then pull it 5 You can check inside of the product if Drain part is something wrong LH105EZM1 LH128EZM1 LH140EZM1 HH105EZM1 HH128EZM1 HH140EZM1 ...

Страница 21: ... Disassemble 1 screw of indicating part then lift up the cover to release from Ass y Control In 2 Detach the capacitor connection wire the Motor Fan in and housing connector from Ass y Control In 3 Disassemble all screws of bottom part Disassemble 2 screws which are located Drain Hole part Bottom Side ...

Страница 22: ...and Reassembly 21 Samsung Electronics No Parts Procedure Remark 4 Detach the Cabinet Base It needs 2 people 5 Disassemble the Bracket Motor and Earth Wire 6 Release the nut of Blower 7 Disassemble Base Blower bolts ...

Страница 23: ...amsung Electronics 22 No Parts Procedure Remark 8 Disassemble One of 2 Blowers 9 Disassemble the Wire Clamp 10 Disassemble the Motor 11 If you did 1 4 you can see inside of the product like the picture right You can clean the Evap ...

Страница 24: ... the power cable 2 Remove the Top Cover 3 Remove the Control Box Cover 4 Unplug the Ass y Cable 5 Remove the Cabi Side 6 Remove the Cabi Front When you assemble the parts check if the each parts and electric connectors are fixed firmly 1 Remove the Nut Flange Turn to the clockwise 2 Disassemble the Propeller Fan UH052EZMC UH070EZMC ...

Страница 25: ...ocedure Remark 1 Outdoor Unit Disassembly Procedure 1 Loosen the 8 screws fixing the Cover Side 2 Loosen the screws and push the Cover Side in the arrow direction for disassembly 3 Disconnect the PCB connector and disassembly the Electronic Box and PCB UH105GZMC ...

Страница 26: ...bly and Reassembly 25 Samsung Electronics No Parts Procedure Remark 4 Disassemble the Cover Top and Front 5 Loosen the bolt to disassemble the Fan 6 Loosen the Motor fixing nut 7 Loosen the Bracket fixing screw ...

Страница 27: ...le 2 Uncover the Top Cover 3 Uncover the Control Box Cover 4 Pull out the assemble Cable 5 Disassemble the Cabinet Side 6 Disassemble the Cabinet Front Check if each part is fixed to the electric connector firmly at the time of part assembly 1 Loosen the Propeller Fan Bolt 2 Disassemble the Fan No Parts Procedure Remark UH128GZMC UH140GZMC ...

Страница 28: ...ling per extension length of 1m When extending the pipe length by more than 5m 30gr of R22 refrigerant should be refilled per extension length of 1m Heat Exchanger Evaporator Heat Exchanger Condensor Cooling Heating Gas leak check point Capillary tube Liquid pipe Gas pipe Compressor Muffle Accumulator 3 Way valve Expansion valve Filter Filter 3 Way valve DH052EZM1 UH052EZMC DH070EZM UH070EZMC ...

Страница 29: ...n length of 1m When extending the pipe length by more than 5m 45gr of R22 refrigerant should be refilled per extension length of 1m Heat Exchanger Evaporator Heat Exchanger Condensor Cooling Heating Gas leak check point Capillary tube Liquid pipe Gas pipe Compressor Muffle Low Pressure Switch Accumulator 3 Way valve Expansion valve Filter Filter 3 Way valve LH105EZM1 HH105EZM1 UH105GZMC 4 Way valv...

Страница 30: ...extension length of 1m When extending the pipe length by more than 5m 50gr of R22 refrigerant should be refilled per extension length of 1m Heat Exchanger Evaporator Heat Exchanger Condensor Cooling Heating Gas leak check point Capillary tube Liquid pipe Gas pipe Compressor Muffle Accumulator 3 Way valve 4 Way valve Expansion valve Filter Filter 3 Way valve LH128EZM1 HH128EZM1 UH128GZMC LH140EZM1 ...

Страница 31: ...sh the button the display panel reads or repeatedly Push the button to set the display panel to Every time you push the button the display panel reads repeatedly Setting is not required if you must a value which has a default 3 Push the button to set the display panel to Every time you push the button the display panel reads repeatedly 4 Push the button to set the display panel to Every time you p...

Страница 32: ...ction key to set the display part to and check the display part The display part shows Press the Mode Selection key to set the display part to and check the display part The display part shows Step 4 Pressing the ON OFF button When pressing the operation ON OFF key with the direction of remote control for unit the sound Ding or Diriring is heard and the OPERATION ICON lamp of the display is flicke...

Страница 33: ...S MODEL REMOTE CONTROL SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 DH052EZM1 DH070EZM 0 1 5 4 4 2 1 c 0 0 0 0 LH105EZM1 0 1 5 4 4 2 1 F 0 0 0 0 HH105EZM1 0 1 5 4 0 2 1 F 0 0 0 0 LH128EZM1 LH140EZM1 HH128EZM1 HH140EZM1 0 1 5 c 4 2 1 3 0 0 0 0 ...

Страница 34: ... side is If SW02 MAIN that set indoor unit address is controlled to indoor unit number marked on outdoor unit is marked by 5 1 2 Option set part for Outdoor unit PCB 5 Control Specification Troubleshooting 5 1 Operation Specification DISPLAY PART DS1 Left Right Counts of Indoor Unit Installation 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 A B C D E F Numbers of the switch Example When th...

Страница 35: ... 3 4 Use the K1 only for heat pump models K1 Displayed on SEG 3 4 Adding refrigerant at heating mode Test operation at heating mode End K2 Displayed on SEG 3 4 Adding refrigerant at cooling mode Test operation at cooling mode Pump Down for recovery of refrigerant End K3 Displayed on SEG 3 4 Reset K4 Displayed on SEG 3 4 Displays data Summary of KEY functions K1 K2 K3 RESET DISPLAY MODE CHECK MODE ...

Страница 36: ...Error of discharge temperature sensor Open Short System down caused by communication error after completion of tracking Mismatching of the indoor unit numbers set with those communication after completion of 5 times tracking Error of temperature sensor in the indoor unit Open Short Error of the heat exchanger sensor in the indoor unit Open Short Error of electronic expansion valve open in the outd...

Страница 37: ...the communication numbers and installed numbers after completion of tracking Communication error for more than 2 minutes Communication error between indoor units 1 Error of electronic expansion valve close 2 Error of electronic expansion valve open 3 2 nd detection of high temperature cond 4 2 nd detection of high temperature discharge 5 Error of reverse phase 6 Compressor down due to 6 th detecti...

Страница 38: ... by communication error after completion of tracking Mismatching of the indoor unit numbers set with those communicated after completion of tracking Error of float switch in indoor unit Error of setting option switches for optional accessories OPEN SHORT error of room sensor in indoor unit OPEN SHORT error of eva in sensor in indoor unit EEPROM option error Error of fan starting Open error of elec...

Страница 39: ...utdoor temp sensor Disconnection or leak of applied sensor Yes No Yes Check the out temp sensor is normal or not by use of out data display part Check the temp data is normal or not after pressing K4 3 times At this time is occurred the difference between the out temp and data Reoperation after PCB replacement Does the out temperature sensor connected to PCB CN41 At this time Is largely deviate th...

Страница 40: ...normal or not after pressing K4 2 times At this time is occurred the difference between the out temp and data Reoperation after PCB replacement Does the out heat exchanger temp sensor connected to PCB CN41 At this time Is largely deviate the resistance value from side table value Measure the resistance value between two terminals after separating the out heat exchanger temp sensor connector from P...

Страница 41: ... after PCB replacement Does the outdoor discharge temp sensor connected to PCB CN42 At this time Is largely deviate the resistance value from side table value Measure the resistance value between two terminals after separating the outdoor discharge temp sensor connector from PCB Temp C 130 120 100 80 60 25 20 10 0 Resistance kΩ 8 9 11 2 18 5 32 59 200 242 362 553 Outdoor unit display Indoor unit d...

Страница 42: ...by each and then replace the indoor unit PCB after line check Check the display after pressing the reset key on outdoor PCB When tracking is there any indoor answer from display part At this time is the voltage between lines rectangular wave over DC 0 7V like below figure 0 7V 0 7V Good Bad Multi type After 2 minutes check if PCB address setting of indoor unit displayed the communication error amo...

Страница 43: ...nit installation numbers To measure the 2 lines of outdoor unit side by use of scope after removing the communication line connecting from outdoor unit to indoor unit Is equal indoor unit actual installation number and installation number setting switch At this time is the voltage between lines rectangular wave over DC 0 7V When tracking is there any indoor answer from display part If address is n...

Страница 44: ... connected to indoor unit PCB Open status Is much the water of drain pan Does the drain pump operate Does the water level decrease Is the same error occurred Is the terminal voltage of drain pump PCB about AC220V Re assembly the floating switch connector and perform the reset of outdoor power Required the reset of indoor unit power Note E3 error should be released when indoor unit power is reset O...

Страница 45: ...ts List 6 1 Indoor Unit 1 2 5 13 18 10 11 19 17 9 4 14 15 7 8 6 16 3 12 19 2 19 6 19 3 19 1 5 1 5 6 5 5 5 4 5 2 5 7 5 3 19 4 19 5 You can search for the updated part code number through the ITSELF URL http itself sec samsung co kr DH052EZM1 DH070EZM ...

Страница 46: ...NLET LF PLATE HANGER LF ASS Y EVAP ASS Y CABI INLET RH ASS Y CABI SIDE RH PLATE HANGER RH CABINET SIDE RH B ASS Y HOLDER OUTLET ASS Y COVER BOTTOM PLATE HANDLE FILTER PRE COVER CONTROL ASS Y CONTROL IN ASS Y CASE CONTROL ASS Y PCB MAIN TERMINAL BOARD 6P CAPACITOR TRANS POWER HOLDER WIRE SGCC M T0 8 SGCC M T0 8 ASS Y BLK SGCC M T0 8 ADH2400B SGCC M T1 2 SGCC M T2 0 ADH2400E ASS Y SGCC M ø175 ASS Y ...

Страница 47: ...ded Views and Parts List Samsung Electronics 46 5 8 1 8 5 8 3 8 7 8 8 2 8 6 4 10 2 10 4 10 6 8 4 7 1 7 2 6 10 1 9 3 7 9 2 10 7 10 1 10 8 10 3 10 5 HH105EZM1 HH128EZM1 HH140EZM1 LH105EZM1 LH128EZM1 LH140EZM1 ...

Страница 48: ...16N ASS Y CONTROL IN 220V 50Hz HH105EZM 1 SA 8 1 DB61 00098A CASE CONTROL SGCC M T0 8 1 1 SNA 8 2 DB26 10065B TRANS POWER 230V 50Hz 1 1 SA 8 3 DB65 00004H TERMINAL BLOCK 6P 6p 1 1 SA 8 4 DB65 00004L TERMINAL BLOCK 6P 6p 1 1 SA 8 5 DB93 00849P ASS Y PCB MAIN DPM DUCT DPM PCB HH140EZM 1 1 SA 8 6 DB61 40291B HOLDER WIRE PP BLK 2 2 SNA 8 7 DB63 01021A COVER CONTROL SGCC M T0 5 1 1 SNA 9 DB90 01513A AS...

Страница 49: ...16M ASS Y CONTROL IN 220V 50Hz HH105EZM 1 SA 8 1 DB61 00098A CASE CONTROL SGCC M T0 8 1 1 SNA 8 2 DB26 10065B TRANS POWER 230V 50HZ 1 1 SA 8 3 DB65 00004H TERMINAL BLOCK 6P 6p 1 1 SA 8 4 DB65 00004L TERMINAL BLOCK 6P 6p 1 1 SA 8 5 DB93 00849Q ASS Y PCB MAIN DPM DUCT DPM PCB HH140EZM 1 1 SA 8 6 DB61 40291B HOLDER WIRE PP BLK 2 2 SNA 8 7 DB63 01021A COVER CONTROL SGCC M T0 5 1 1 SNA 9 DB90 01513A AS...

Страница 50: ...MEMO 49 Samsung Electronics ...

Страница 51: ...Samsung Electronics 50 6 2 Outdoor Unit 5 4 6 7 8 11 10 15 13 14 16 18 17 12 1 12 3 9 3 1 2 12 2 UH052EZMC UH070EZMC ...

Страница 52: ...484A ASS Y CONTROL OUT HP UH070EZM 1 SNA 9 DB67 30081C PARTITION ASM 3500A 1 SA 10 DB95 00201A ASS Y COMP APH2416 SHV33C6 G HITACHI 1 SA 11 DB60 30028A NUT WASHER HEX 2C M8 ZPC 3 SNA 12 1 DB67 00379A ACCUMULATOR ACE 23ZA3 UH070EZMC 1 SNA 12 2 DB96 02902A ASS Y 4 WAY VALVE ASS Y 1 SA 12 3 DB96 02903A ASS Y EXPANSION VALVE ASS Y 1 SA 13 DB98 02909E ASS Y COND PART UH070EZMC CHINA 1 SA 14 DB90 10616G...

Страница 53: ...Exploded Views and Parts List Samsung Electronics 52 9 8 7 6 1 25 26 27 15 11 3 10 5 4 14 12 13 28 24 23 20 21 17 16 18 19 22 2 UH105GZMC ...

Страница 54: ...NET FRONT RH UH105GZMC SSEC 1 SA 12 DB67 00467A PARTITION UH105GZMC 1 SA 13 DB97 02613A ASS Y BRACKET VALVE ASS Y SGCC M T1 6 SSEC 1 SA 14 DB61 01582A CASE PCB UH070EZM ABS 2 5 BLACK DPM 5V 1 SA 15 DB93 02762B ASS Y CONTROL OUT HP SCROLL R22 UH105GZMC 1 SNA 16 DB90 01594A ASS Y CABINET BACK RH UH105GZMC SSEC 1 SA 17 DB96 03684A ASS Y BASE PLATE OUT UH105GZMC SSEC 1 SA 18 DB97 02601A ASS Y ETC INSU...

Страница 55: ...Exploded Views and Parts List Samsung Electronics 54 16 14 10 11 9 27 26 23 18 13 15 19 4 25 17 24 20 2 3 5 6 22 21 12 1 7 8 UH128GZMC UH140GZMC ...

Страница 56: ... UH105GZMC C3771 C3604 CR 3 8 FLARE TYPE 1 SNA 12 DB96 03662A ASS Y COND UNIT UH140GZMC SSEC BENDING 1 SNA 13 DB99 00604A ASS Y VALVE 4 WAY UH140GZMC SSEC 1 SA 14 DB99 00495A ASS Y SCROLL COMP SANYO UH140GZMC SSEC 1 SA 15 DB99 00606A ASS Y VALVE EXPANSION UH140GZMC SSEC 1 SA 16 DB97 02601A ASS Y ETC INSU SOUND UH140GZMC SSEC 1 SA 17 DB95 00564B ASS Y HEATER COMP UH140GZMC CHINA 1 SA 18 DB32 00102B...

Страница 57: ...on EEPROM option saving and blackout restoring function Power comm line misconnection prevention function Cost saving related sub option separation between indoor unit communication part Option part sub development according to the SVC structure Blackout restoring function RMC ADDRESS setting part MAIN PCB MICOM 485 comm control Central control Wired remote controller Relay Central controller Indo...

Страница 58: ...57 Samsung Electronics This Document can not be used without Samsung s authorization 8 Wiring Diagram 8 1 Indoor Unit Code No DB98 12868A DH052EZM1 DH070EZM ...

Страница 59: ...Wiring Diagram Samsung Electronics 58 This Document can not be used without Samsung s authorization Code No DB98 20414A HH105EZM1 HH128EZM1 HH140EZM1 LH105EZM1 LH128EZM1 LH140EZM1 ...

Страница 60: ...59 Samsung Electronics This Document can not be used without Samsung s authorization 8 2 Outdoor Unit Code No DB98 13916A UH052EZMC UH070EZMC ...

Страница 61: ...Wiring Diagram Samsung Electronics 60 This Document can not be used without Samsung s authorization Code No DB98 22302A UH105GZMC ...

Страница 62: ...Wiring Diagram 61 Samsung Electronics This Document can not be used without Samsung s authorization Code No DB98 22303A UH128GZMC UH140GZMC ...

Страница 63: ...Samsung Electronics 62 This Document can not be used without Samsung s authorization 9 Schematic Diagram 9 1 Indoor Unit DH052EZM1 DH070EZM ...

Страница 64: ...63 Samsung Electronics This Document can not be used without Samsung s authorization HH105EZM1 HH128EZM1 HH140EZM1 LH105EZM1 LH128EZM1 LH140EZM1 ...

Страница 65: ...Samsung Electronics 64 9 2 Outdoor Unit This Document can not be used without Samsung s authorization UH052EZMC UH070EZMC ...

Страница 66: ...Schematic Diagram 65 Samsung Electronics Indoor unit power part 3 phase Communi cation This Document can not be used without Samsung s authorization UH105GZMC UH128GZMC UH140GZMC ...

Страница 67: ...MEMO Samsung Electronics 66 ...

Страница 68: ...MEMO 67 Samsung Electronics ...

Страница 69: ...MEMO Samsung Electronics 68 ...

Страница 70: ...e Manual is a property of Samsung Electronics Co Ltd Any unauthorized use of Manual can be punished under applicable International and or domestic law Samsung Electronics Co Ltd Apr 2006 Printed in China Code No DB98 22143A 3 ...

Отзывы: