background image

View of the Unit 

The figures shown in this instruction may differ from yours depending on the model.

E-

4

Air flow blades(outlet)

Air inlet

Air filter(under the grille)

Indoor Unit

TYPE A

Indoor Unit

TYPE B

Timer indicator

Remote control sensor

On/Off button
On/Off indicator
Fan indicator

Removing frost indicator 

Filter Sign indicator

Air flow blades(outlet)

Air inlet

Air filter(under the grille)

Timer indicator

Remote control sensor

On/Off button

On/Off indicator

Fan indicator

Removing frost indicator 

Filter Sign indicator

Содержание UH052EZMC

Страница 1: ... System Kühlen und Wärmen ÛÙËÌ ÏÈÌ ÙÈÛÌÔ æ ÍË Î È ÚÌ ÓÛË ëËÒÚÂÏÌ È ÇÓÁ Û Ì È äÓÌ ËˆËÓÌ éıÎ Ê ÂÌËÂ Ë Ó Ó Â E S F I P D G R DB98 22138A 2 E HNIKA ENGLISH ESPAÑOL FRANÇAIS ITALIANO DEUTSCH PORTUGUÊS RUSSIAN CH052EZM1 CH070EZM CH105EZM1 CH128EZM1 CH140EZM1 Indoor Unit UH052EZMC UH070EZMC UH105GZMC UH128GZMC UH140GZMC Outdoor Unit OWNER S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D UTILISATION ISTRU...

Страница 2: ... than 7 meters from the air conditioner If applicable WARNING DURING OPERATION Never store or ship the air conditioner upside down or sideways to avoid damage to the compressor The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance Max current is measured according to IEC s...

Страница 3: ...separate collection systems This marking shown on the product or its literature indicates that it should not be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resourc...

Страница 4: ...lle Indoor Unit TYPE A Indoor Unit TYPE B Timer indicator Remote control sensor On Off button On Off indicator Fan indicator Removing frost indicator Filter Sign indicator Air flow blades outlet Air inlet Air filter under the grille Timer indicator Remote control sensor On Off button On Off indicator Fan indicator Removing frost indicator Filter Sign indicator ...

Страница 5: ...heat exchanger in the outdoor unit gets dusty cooling efficiency may fall So clean the heat exchanger with water when it becomes dirty However be careful when you wash the surface of the heat exchanger because it is very sharp N N N No o o ot t t te e e e Outdoor Unit UH105GZMC Outdoor Unit UH128GZMC UH140GZMC Outdoor Unit ...

Страница 6: ...on Swing button On Timer button Off Timer button On Off Timer Set Cancel button Fan speed adjustment button Temperature adjustment buttons Temperature setting Fan speed Air flow direction On Timer setting Off Timer setting Battery discharge indicator The wireless remote controller is an optional accessory To use the wireless remote controller refer to an appropriate manual E 6 ...

Страница 7: ... FILTER SIGN indicator when the time to clean the air filter refer to page 12 N N N No o o ot t t te e e e Mode selection button Communication error indicator On Timer setting Off Timer setting Test indicator Timer button Timer Set Cancel button Test button Temperature adjustment buttons Removing frost indicator Operating mode Centralized controller indicator In case of installing the Centralized ...

Страница 8: ...f button On Off indicators On Off buttons Index The operating lamp comes on even when only one air conditioner connected to the centralized controller is operating N N N No o o ot t t te e e e Front View Operating Mode Switch COOL AUTO HEAT Choose the appropriate operating mode with the Operating Mode Switch that enables the user to choose between the Cool Auto Heat mode N N N No o o ot t t te e e...

Страница 9: ...t button Swing button Temperature adjustment buttons Temperature setting Fan speed Air flow direction Filter Sign indicator On Off Timer Set Cancel button Fan speed adjustment button On Off indicator Centralized controller indicator Communication error indicator Removing frost indicator Except Cooling Only Models Operating mode The button is for your installation specialist You must NOT press it A...

Страница 10: ...high frost may form on the outdoor unit at HEAT mode If this happens The heating operation stops The defrost mode will be triggered automatically for 3 to 14 minutes No intervention is required after about 10 minutes the air conditioner operates again normally Frost If both indoor and outdoor temperatures are high and the air conditioner is running at HEAT mode the outdoor unit s fan and compresso...

Страница 11: ...may condense on and drip from the surface of the indoor unit if it is used for a long periods High humidity levels The standardized temperature for heating is 7 C If the outdoor temperature drops to 0 C or below the heating capacity can be reduced depending on the temperature condition If the cooling operation is used at over 32 C indoor temperature it does not cool at its full capacity Mode Outdo...

Страница 12: ...inished insert the filter into the front grille 6 Clean the unit with a vacuum cleaner or a brush once a month 7 Reinstall the front grille and the safety clips 8 IMPORTANT You must give attention when disassembling the front grille and must check the safety clips have been installed If you do not check them the front grille will drop suddenly and you will be hurt IMPORTANT After cleaning the air ...

Страница 13: ...ecure the bio pure filter with four screws 6 Reinstall the air filter the front grille and the safety clips 7 Do not remove the packing from a bio pure filter until you wish to use the filter as it will lose its properties N N N No o o ot t t te e e e The air conditioner can be fitted with a Bio Pure filter to remove minute dust particles The service life of the filter is approximately 3 months de...

Страница 14: ... the correct operating mode has been selected The room temperature may be too low or too high Dust may be blocking the air filter guard refer to page 12 for cleaning instructions Check that there is no obstacle in front of the outdoor unit The air conditioner does not operate with the remote controller Wireless Remote Controller Wireless Remote Controller No beep is heard when you press On Off on ...

Страница 15: ...E 15 ENGLISH Technical Specifications Power Supply Model 1Ø 220 240V 50Hz CH052EZM1 CH070EZM CH105EZM1 CH128EZM1 CH140EZM1 ...

Страница 16: ...ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR QUESTO CONDIZIONATORE D ARIA È PRODOTTO DA ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR DIESE KLIMAANLAGE IST FABRIZIERT VON AYTH H Y KEYH KATA KEYA THKE A O ùíéí äéçÑàñàéçÖê àáÉéíéÇãÖç îàêåéâ ...

Отзывы: