background image

RS232C Command Code (UF-80)

5

English

French

German

Italian

Spanish

Focus FAR

0 x 25

0 x 00

0 x 05

0 x 00

0 x 25

"ACK data"

0 x 05

0 x 00

Focus NEAR

0 x 00

0 x 0A

0 x 00

"ACK data"

0 x 0A

0 x 00

Zoom Tele

0 x 26

0 x 00

0 x 05

0 x 00

0 x 26

"ACK data"

0 x 05

0 x 00

Zoom Wide

0 x 00

0 x 0A

0 x 00

"ACK data"

0 x 0A

0 x 00

Iris Target

0 x 41

0 x 00

0 x 00

"data"

0 x 41

"ACK data"

0 x 00

"data"

Range: "1~120"

Red Target

0 x 43

0 x 00

0 x 00

"data"

0 x 43

"ACK data"

0 x 00

"data"

Range: "1~200"

Blue Target

0 x 44

0 x 00

0 x 00

"data"

0 x 44

"ACK data"

0 x 00

"data"

Range: "1~200"

Focus Target

0 x 45

0 x 00

"MSB data" "LSB data"

0 x 45

"ACK data" "MSB data" "LSB data"

(1)

Range: "0~2225"

Zoom Target

0 x 46

0 x 00

"MSB data" "LSB data"

0 x 46

"ACK data" "MSB data" "LSB data" Range: "0~1904"

Focus/Zoom

0 x 47

0 x 05

"zoom MSB" "zoom LSB"

0 x 47

"ACK data" "zoom MSB" "zoom LSB"

(1)

Focus: "0~2225"

concurrent Target

0 x 0A

"focus MSB" "focus LSB"

"ACK data" "focus MSB" "focus LSB"

Zoom: "0~1904"

(1)

Drive Stop

0 x 2F

0 x 00

0 x 05

0 x 00

0 x 2D

"ACK data"

0 x 05

0 x 00

1st

2nd

3rd

4th

PC Transmit Data to MICOM

Command

Remark

PC Receive Data from MICOM

1st

2nd

3rd

4th

[Note 1]

Depending of the zoom amount, the range of focus data will be changed. You can figure it out to see
page 4. ("Focus-Status[Max]", "Focus-Status[Min]")

[Note 2]

Above 10 Command (Iris up/down ,Red up/down, Blue up/down, Focus far/near, Zoom tele/wide) will
go to all the way once you execute it. 
"Drive Stop" can stop those command in certain point that you want.

Содержание UF-80DX

Страница 1: ...English French German Italian Spanish...

Страница 2: ...te Check Command 0xB0 0x64 0x00 0x00 0x00 0xBF Receive 6 byte from MICOM 2nd Rx data 0x80 Send User AWC etc Command BaudRate 9600bps Parity Bit No Parity Stop Bit Length 1 bit Character Length 8 bit S...

Страница 3: ...00 0 x 09 ACK data 0 x 05 0 x 00 Aperture OFF 0 x 00 0 x 0A 0 x 00 ACK data 0 x 0A 0 x 00 FREQ 75Hz 0 x 0A 0 x 00 0 x 05 0 x 00 0 x 0A ACK data 0 x 05 0 x 00 FREQ 60Hz 0 x 00 0 x 0A 0 x 00 ACK data 0...

Страница 4: ...00 Range 1 4 Preset Exe 0 x 18 0 x 00 Number 0 x 00 0 x 18 ACK data Number 0 x 00 Recall divide 3x3 multi screen 0 x1F 0 x 00 0 x 05 0 x 00 0 x 1F ACK data 0 x 05 0 x 00 Cancel Iris Up 0 x 21 0 x 00...

Страница 5: ...a LSB data 1 Range 0 2225 Zoom Target 0 x 46 0 x 00 MSB data LSB data 0 x 46 ACK data MSB data LSB data Range 0 1904 Focus Zoom 0 x 47 0 x 05 zoom MSB zoom LSB 0 x 47 ACK data zoom MSB zoom LSB 1 Focu...

Страница 6: ...8 0 x 00 0 x 00 0 x 00 0 x 68 ACK data 0 x 00 Status Range 1 200 Zoom Status 0 x 69 0 x 00 0 x 00 0 x 00 0 x 69 ACK data Status MSB Status LSB Range 0 1904 Focus Status 0 x 6A 0 x 00 0 x 00 0 x 00 0 x...

Страница 7: ...command by panel key 0 0 0 1 0 Set is executing command by remocon 0 0 1 0 0 Set is executing command by RS232C 0 1 0 0 0 Set is executing command by USB 1 0 0 0 0 Set is executing command by MOUSE 0...

Страница 8: ...0 1 NO SYNC EXT 1 1 1 external input 0 lamp OFF 1 lamp ON 0 System Power OFF 1 System Power ON 0 Aperture ON 1 Aperture OFF 0 Frequency 75Hz 1 Frequency 60Hz Status Bit Definition by Set Status Comman...

Страница 9: ...ber8 Status Bit Definition by Set Status Digital Command LSB 8bit 7 6 5 4 3 2 1 0 0 image divide OFF 1 image divide ON 0 3X3 multi screen OFF 1 3X3 multi screen ON 0 image freeze OFF 1 image freeze ON...