E-
17
ENGLISH
The electric
component
box cover
The safety net
Installing the Safety Net & Air blocking kits
Technical Specification & Product feature
Model
TH026EAV1
TH035EAV1
TH052EAV1
TH060EAV1
Capacity (Cooling and Heating)
2600/3300
3500/4000
4700/5500
5800/7000
Power input
730/900
1090/1100
1460/1590
1930/2180
Running current
3.4/4.3
5.0/5.1
6.7/7.4
8.8/10.0
Refrigerant
950g
950g
1450g
1500g
Fuse
1.6A
1.6A
1.6A
1.6A
Maximum installation height: up to 3.6m
Condensate discharge pump(built-in): Max. 550mm
Length of pipes and difference in height: see the outdoor unit installation manual
Vacuum and refrigerant charge: see the outdoor unit installation manual
Install the safety net after installing the connection cord and fixing electric
component box cover. For your safety, you must install the safety net.
For details about installing the panel, refer to the manual for the panel.
1
Uncover the wrap of safety net.
2
Fix the safety net to the electric component cover box with four screws as
indicated.
Safety net
1
When installing the unit depending on the situation, you can fill up the air
outlet(s) with one or two (max.) air blocking kits (not supplied). Then install
the insulation to block air completely.
If the humidity goes over 65%, do not block more than 2 air blocking kits.
Air blocking kits
Air blocking
kits
Insulation
TH026EAV IM_E_24340.indd 17