![Samsung TDM PLUS Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/samsung/tdm-plus/tdm-plus_service-manual_4019237077.webp)
Troubleshooting
Samsung Electronics
77
No.
LED Display
Displayed
PCB Assy
Meaning
Remarks
Error Code
Red
Green
Yellow
24
z
|
z
MAIN/INVERTER
Comp. wire missing error
Check Comp. wire
E467
25
z
MAIN/INVERTER
Current sensor error
Check Outdoor Inverter
PBA
E468
26
z
|
MAIN
DC-Ling voltage
Sensor error
Check Input
voltage
E469
27
z
|
MAIN
EEPROM read/write error
Check EEPROM
E470
28
z
|
MAIN
Outdoor EEPROM error
Check Outdoor EEPROM
date
E471
29
|
MAIN/INVERTER
IPM(IGBT Module) or PFCM Temperature sen-
sor Error
Check Outdoor Inverter
PBA
E474
30
z
z
MAIN/INVERTER
PFC Overload Error
Check Outdoor Inverter
PBA
E484
31
z
|
MAIN
Input current
sensor error
E485
32
|
MAIN/INVERTER
IPM is over heated.
Check Outdoor Inverter
PBA
E500
33
z
|
MAIN
GAS Leak error
Check indoor and outdoor
unit model
E554
34
z
|
MAIN
Water inlet
temperature sensor error
Check Water
inlet sensor
E901
35
z
|
MAIN
Water outlet
temperature sensor error
Check Water
outlet sensor
E903
36
z
|
MAIN
Refriqerant gas inlet
temperature sensor error
Check Gas
inlet sensor
E906
37
z
|
MAIN
Mixing Valve Outlet
temperature sensor error
Check Mixing Valve
Outlet sensor
E916
|
Off
Blink
z
On
4-5-2 Troubleshooting for outdoor unit(con.)
If an error occurs during the operation, it is displayed on the outdoor unit PCB LED, both MAIN PCB and INVERTER PCB.
Содержание TDM PLUS
Страница 42: ...Disassembly and Reassembly 42 Samsung Electronics No Parts Procedure Remark ...
Страница 54: ...Disassembly and Reassembly 54 Samsung Electronics No Parts Procedure Remark ...
Страница 62: ...62 Samsung Electronics 4 Troubleshooting 4 1 Error Display AE090 120 160MXTP AE044 066MXTP ...
Страница 107: ...Samsung Electronics 107 This Document can not be used without Samsung s authorization 6 1 2 3Phase Model ...