4.2.3 RAID0+1
During the RAID0+1 mode, when a SATA hard drive fails, replace it and then rebuild the RAID
array.
-
During the RAID0+1 mode, when a SATA hard drive fails, the SVS-5R activates beeping
sounds and the RAID error LED. To disable the beeping sounds, open the front panel using
the access panel lock, and then press the mute switch. The front LCD will display the SVS-5R
status as Degraded. d:FOOO; indicating a failed SATA hard drive.
-
When the failed SATA hard drive is replaced with a new one, the LCD displays the following
message. Press the left button to start rebuilding the RAID array.
-
During the rebuilding process, the front LCD displays the following message. It indicates a
rebuilding SATA hard drive, and the time remaining until completion.
-
When the RAID array is successfully rebuilt, the front LCD displays the following message.
SVS-5R R0+1 4d
d:OOOO
Rebuild d:ROOO
1h:31m
RAID rebuilding?
<-Okay?
Degraded R0+1 4d
d:FOOO