Installation and Connection
32
2004. 07. 2004 (v 1.0)
Samsung Techwin
9.2 Connecting and Setting Relay Output
9.2.1 Specification
The alarm output of the SVR-1630 has the specifications and normal operating conditions as described
below.
No. of Output Circuits
Automatic output of 4 Relays
Output Method
Dry Contact
Spec.
Connection
Connect the stripped wires to the Terminal Block.
24V DC, 1.25A, 30W
DC
125V DC, 0.24A, 30W
125V AC, 0.5A, 62.5VA
Rated
Values
AC
250V AC, 0.25A, 62.5VA
9.2.2 Connecting to Relay Output Terminal
For connection of R1 ~ R4 outputs, see the figure below. The figure below is an example for connecting
the warning lamp. For connecting or removing wires, see “Wiring” on page
28
.