SVM-400 Voice Mail System                                                                                                 Installation Manual 

 

 

CHAPTER 2 SVM-400 System Installation 

 
 
This chapter describes the installation procedures for the SVM-400 system, including precau- 
tions for your safety. Read this chapter carefully before installing the system. 

 

 

 

Environmental Requirements

 

 

o

  Temperature:                          0°–40°C (32°–104°F) 

o

 

Relative 

Humidity:                   Maximum 90% (non-condensing) 

o

  Power Specifications:            Power supply of 60 or more watts 

 220VAC–240VAC, 

1.6A 

o

  Regular Frequency:               50Hz 

 

 

Keep the unit away from static electricity and electrical noise

 

 

If there is a  possibility of static electricity or electrical “noise” occurring where the system is 
installed (due to carpets, electrical machinery, etc), measures for preventing this should be put 
in place. 

 

 

Install the unit where it is not exposed to harmful conditions

 

 

Be careful not to expose the system to direct sunlight, corrosive vapour, dust, regular vibration 
or high levels of magnetic fields generated by motors or copying machines. 

 

 

 

Precautions for Installation

 

 

 

Selecting Location

 

 

Select a location having sufficient space and levels of brightness to facilitate installation. 

 

 

Preventing Static Electricity

 

 

The unit should not be installed in a room with carpets. To ensure safety, discharge any static 
electricity by touching the metal portion of a grounded object or the ground connection on the 
system before installing or repairing the system. 

 

In addition, for protection and reliable operation of the system, standard grounding conditions 
should be met. 

 

 

Cable Requirements

 

 

Select a location which minimises the length of system cables, and ensure that all cables to and 
from the system are not damaged. In addition,  take  care to protect all  cables from elec- 
tromagnetic interference; for instance, by keeping them at a safe distance from cables for other 
equipment. 

 

 

 

 

– 4 – 

Содержание SVM-400

Страница 1: ...Voice Mail System Installation Manual SVM 400 ...

Страница 2: ...Disclaimer Samsung Business Communications is not responsible for errors or problems arising from customers not installing programming or operating their Samsung systems as described in this manual Copyright 2004 Samsung Business Communications All rights reserved No part of this manual may be reproduced in any form or by any means graphic electronic or mechanical including recording taping photoc...

Страница 3: ...2 1995 Inc A1 A2 1998 EN61000 3 3 1995 EN61000 4 2 1995 Inc A1 1998 EN61000 4 3 1996 Inc A1 1998 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 8 1993 EN61000 4 11 1994 AS NZS3548 1995 EN60950 1992 A1 A2 A3 A4 A11 Manufacturer Samsung Electronics Co Ltd 259 Gongdan Dong Gumi City Kyungbuk Korea 730 030 Tae eok Jang General Manager place and date of issue name and signature of authori...

Страница 4: ...1998 A1 2001 A2 2003 EN61000 3 2 2000 EN61000 3 3 1995 A1 2001 EN61000 4 2 1995 A1 1998 A2 2001 EN61000 4 3 2002 EN61000 4 4 1995 A1 2001 A2 2001 EN61000 4 5 1995 EN61000 4 6 1996 A1 2001 EN61000 4 11 1994 A1 2001 EN60950 1999 Corr Jan 2000 Manufacturer Samsung Electronics Co Ltd 259 Gongdan Dong Gumi City Kyungbuk Korea 730 030 Tae eok Jang General Manager place and date of issue name and signatu...

Страница 5: ... 2001 EN61000 3 2 1995 Inc A1 A2 1998 EN61000 3 3 1995 EN61000 4 2 1995 Inc A1 1998 EN61000 4 3 1996 Inc A1 1998 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 8 1993 EN61000 4 11 1994 AS NZS3548 1995 EN60950 1992 A1 A2 A3 A4 A11 Manufacturer Samsung Electronics Co Ltd 259 Gongdan Dong Gumi City Kyungbuk Korea 730 030 Tae eok Jang General Manager place and date of issue name and sign...

Страница 6: ... 2001 EN61000 3 2 1995 Inc A1 A2 1998 EN61000 3 3 1995 EN61000 4 2 1995 Inc A1 1998 EN61000 4 3 1996 Inc A1 1998 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 8 1993 EN61000 4 11 1994 AS NZS3548 1995 EN60950 1992 A1 A2 A3 A4 A11 Manufacturer Samsung Electronics Co Ltd 259 Gongdan Dong Gumi City Kyungbuk Korea 730 030 Tae eok Jang General Manager place and date of issue name and sign...

Страница 7: ...ion 4 Environment Requirements 4 Precautions for Installation 4 Unpacking the System 5 Procedure for Removing Covers 6 Installation Procedure 7 Grounding 7 Fixing the System on the Wall Optional 10 Testing Initial System Operation 11 Installing the Battery 12 Installing Cables 14 Connecting the Keyphone System 15 Replacing System ROMs 16 Appendix A System Specifications 17 ...

Страница 8: ... VIP DCS 816 DCS 408 or DCS 408i keyphone system System Features o Simple and slim design o Easy to install o Supports 2 or 4 port versions to handle 2 or 4 calls simultaneously For a full description of system features capabilities and operation refer to the Samsung SVMi 2 SVMi 4 SVM 400 Voice Mail Systems Technical Manual and User Guide Front View of System Front cover Side cover SVM 400 1 ...

Страница 9: ...amsung SVM 400 Voice Mail System Installation Manual System Ports After Removing Side Cover Flash card DLI ports Digital line interface ports 21 24 SIO port For RS 232C Battery port Rear View of System 2 ...

Страница 10: ...rce May cause a fire Precautions on Use Do not attempt repair or modification yourself Contact a service centre if repair is required If abnormal sounds smells or smoke come from a telephone immediately unplug the telephone line and contact a service centre If the unit is left in this state a fire may result Precautions on Cleaning Do not spray cleaning fluids directly on the unit and do not clean...

Страница 11: ...Be careful not to expose the system to direct sunlight corrosive vapour dust regular vibration or high levels of magnetic fields generated by motors or copying machines Precautions for Installation Selecting Location Select a location having sufficient space and levels of brightness to facilitate installation Preventing Static Electricity The unit should not be installed in a room with carpets To ...

Страница 12: ...r with other machines problems from noise mal functioning due to voltage drops or fire may result Moreover interruption of power at night may cause malfunctioning and breakdown of the battery CAUTION Always use a dedicated stable AC power supply for the system Unpacking the System Unpack your SVM 400 system and check that there is no damage to any item If you dis cover any damage contact your deal...

Страница 13: ... the Side Cover Viewed from the top the small cover on the right hand side is the side cover A round indent in the side cover is marked PUSH To remove the side cover push it to the right while gently pressing the indent Removing the Front Cover After removing the side cover loosen the four screws holding the front cover as shown Two are located under the side cover and two are on the base of the u...

Страница 14: ...hone system from lightning strikes static electricity and other sources of instant high voltage The AC power supply normally includes a ground connection If for any reason it does not separate external grounding should be done as described here Separate grounding should also be done if the AC power supply does include grounding but there is a problem Incorrect grounding may cause a malfunction in ...

Страница 15: ... earlier A green cable with a yellow stripe is soldered to the grounding end of the AC power cable connection labelled AC INPUT inside the system unit The other end of the green cable is attached to the FRG lug on the power board Fig 1 Green cable soldered to the AC INPUT Lug Lug Figure 1 2 Cut the green cable soldered to the AC INPUT about 2 3cm 1 inch from the soldered end Fig 2 2 3 cm Fig 1 Fig...

Страница 16: ...ure 3 4 Prepare an AWG 10 2 6mm cable for connecting to an external ground and connect it to the ground Insert the cable into the groove on the base of the unit and connect it to the green cable you inserted in the groove at step 3 There are two ways to connect the cables O solder the ends of the two cables together or O expose sufficient wire on both cables to twist them together tightly Fig 4 Tw...

Страница 17: ...f system three 1 Drill three holes in the wall at the positions indicated for the screws using an electric drill CAUTION If the wall is made of plaster or brick or if the building is prefabricated you should fix a wooden board having a thickness of about 2 cm to the wall and drill the holes in this Otherwise you may damage the wall 2 Insert the screws into the holes you drilled If the wall is made...

Страница 18: ...flashing Red LED flashes If the red LED lights but does not flash Turn off the power and remove the trunk board Turn on the power again and see if the red LED flashes If the red LED flashes the trunk board is defective Contact your dealer or the Sam sung Technical Support department for advice If the red LED still does not flash the baseboard is defective Contact your dealer or the Samsung Technic...

Страница 19: ... Discharge Minimum load current A 0 0 04 Maximum load current A 0 3 0 4 Rated output current A 0 1 0 2 Rated output voltage V 54 48 Current consumption of general telephone 30mA How to Install the Battery WARNING Ensure the mains power is switched ON before connecting the battery Failure to do so may result in severe injury 1 Connect the red lead of the battery connection cable to the positive ter...

Страница 20: ...and side of the unit Connect the end of the battery connection cable to this port Battery cable Battery port BATT 4 Turn off the AC power switch and check that the system operates normally 5 Turn on the AC power switch again NOTE During a power failure a battery lasts for a minimum of 4 hours if its capacity is DC 48V 6AH and for a minimum of 8 hours if its capacity is DC 48V 12AH The expected dur...

Страница 21: ...stem after removing the side cover The location of each jack is shown below DLI 1 DLI 2 DLI 3 DLI 4 NOTE These cables are not supplied with your system and should be prepared separately Tying the Cables You should tie all the cables using the cable ties supplied with your system after completing the cabling to the modular jacks 14 ...

Страница 22: ...lightning strikes are possible Do not install a telephone jack in a wet location if the jack is not specially manufactured for use in a wet location Do not touch telephone lines or interface terminals when they are connected with the telephone lines The SVM 400 system provides four ports DLI1 DLI4 Connect these to the DLI ports on the keyphone system using a pair of cables such as 24 AWG 0 5mm or ...

Страница 23: ...nt covers of the system unit as described earlier 4 If an external battery is installed remove it 5 There are two ROMs on the system baseboard Remove these ROMs using a chip extractor and keep them safe for reinstallation in case of emergency SVM 400 6 Install the new ROMs with care in the designated locations ODD1 and EVEN1 7 Reconnect the power cable switch on the power and check that the system...

Страница 24: ... Temperature 0 40 C 32 104 F Relative Humidity non condensing 10 90 Storage Temperature Min Max 10 50 C 14 122 F Line Specifications Item Specifications Digital Keyset 2 line cable max 400m AWG 24 0 5 mm System Dimensions Height mm Width mm Depth mm Weight kg 190 350 60 2 0 17 Item Specifications AC Input 220 240 VAC 50Hz 1 6A Maximum Power Consumption 44 Watts ...

Страница 25: ...Samsung Business Communications Brookside Business Park Greengate Middleton Manchester M24 1GS ...

Отзывы: