User Guide
STAR N02
2
Maximum driver quantity per serial connection is limited. Using more quantity per run will cause overload from SMPS which
damages all connected products. This will cause voltage drop and also dimmed lighting output.
CAUTION
Keep extension lead
wires as short as possible.
Refer to below table for
specific length.
CONNECTION GUIDE
Power Supply
AC Input
DC Output
Make sure that each run should have 50 modules at max
and should use another run in parallel to connect more
Should use thicker wires which can take larger amount of current
than the amount transmitted from the power supply unit
1st
2nd
49th
50th
1st
2nd
49th
50th
1st
2nd
49th
50th
1st
2nd
49th
50th
1st
2nd
Use recommended length for pitch between each module to achieve optimum lighting output while maintaining lowest unit
cost. Failure or misplacing will cause dimmed spots or uneven appearance of light on the surface.
LAYOUT DENSITY
GUIDELINES
RECOMMENDED PITCH PER DEPTH
100 mm
100 mm
120~150 mm
120 mm
90 mm
80 mm
70 mm
80 mm
RECOMMENDED LAYOUT DENSITY PER CHANNEL WIDTH
80 mm
200 mm
400 mm
316 mm
Use 10% shorter length
than usual for circular arrange
CONNECTION WITH
POWER SUPPLY
Output (W)
Model Name
Max Q’TY - Colors*
Recommended
Extension Wire
Output (A)
Max Q’TY - White*
Maximum Length
30W
2.5A
PSCS-0030-12
5M (15FT)
VCTF1.25
AWG18
60W
5A
PSCS-0060-12
5M (15FT)
VCTF2.0
AWG14
120W
10A
PSCS-0120-12
5M (15FT)
VCTF2.0
AWG12
600W
50A
PSCS-0600-12**
15M (50FT)
VCTF5.5
AWG4
1000W
83A
PSCS-1000-12**
15M (50FT)
VCTF8.0
AWG2
EXTENSION OF POWER SUPPLY LEAD WIRES
*Maximum quantity for S-LED is based on 85% of specified capacity of power supplies for extended lifespan
**PSCS-0600-12, PSCS-1000-12 are not weather-proof
Equip with protective box for outdoor use and the box should have ventilating holes
60pcs
40pcs
120pcs
78pcs
240pcs
155pcs
1200pcs
780pcs
2000pcs
1300pcs
DAEHANTRANS CO.,LTD
#7-11 Songdo-Dong, Yeonsu-Gu, Incheon, Korea
Tel. +82 32 858 0491 Fax. +82 32 832 8421 [email protected] / www.daehantrans.com