background image

English

 _ 7

PRODUCT INTRODUCTION

CABLE COLOR SCHEME

2-PIN Connector

I/O Pins

Signal

Cable Color

Power (+12V)

DC +12V

Red

Earth-grounding

GND (-)

Black

6-PIN Connector

I/O Pins

Signal

Cable Color

Wiegand Data Output 0

WIK_DATA0

Green

Wiegand Data Output 1

WIK_DATA1

White

Not Used

Not Used

Orange

RS-232 TX

TX OUT

Purple

Not Used

Not Used

Brown

RS-232-GND

GND

Black

8-PIN Connector

I/O Pins

Signal

Cable Color

Tamper Switch NC

Tamper NC

Green with White Stripes

Tamper Switch COM

Tamper COM

Gray

LED Control

Red LED Control

White with Red Stripes

LED Control

Green LED Control

Yellow

LED Control

Orange LED Control

Blue with White Stripes

Buzzer Control

BUZZER Control

Blue

Not Used

Not Used

Pink

Not Used

Not Used

Sky Blue

CABLE SELECTION

Item

Cable Type

1

Power (DC12V)

Belden #9409, 18 AWG 2 Conductor, Unshielded 

2

Card/PIN data (Wiegand) 

Control Signal (LED,BUZZER) 

TAMPER

Belden #9512, 22 AWG 4 Conductor, Shielded  

Belden #9514, 22 AWG 8 Conductor, Shielded 

3

RS-232 Cable

Belden #9829, 24 AWG  2-twisted pair, Shielded 

Содержание SSA-R2003

Страница 1: ...RFID Reader user manual SSA R2003 imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please visit our website www samsungsecurity com ...

Страница 2: ...ns metal parts etc or containers filled with water on top of the controller Doing so may cause personal injury due to fire electric shock or falling objects Do not install the unit in humid dusty or sooty locations Doing so may cause fire or electric shock If any unusual smells or smoke come from the unit stop using the product In such case immediately disconnect the power source and contact the serv...

Страница 3: ...antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 7 8 9 1 2 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth...

Страница 4: ...TALLATION AND EXTERNAL CONNECTION 8 8 Installation 9 Precautions on installation 10 External Connection INITIALIZATION 11 11 Output Format 12 Basic Operations OUTPUT FORMAT 13 13 WIEGAND Output 14 RS 232 Output 15 4 8 BIT BURST Output Format TROUBLE SHOOTING 16 16 Trouble Shooting PRODUCT SPECIFICATION 17 17 Product Specification ...

Страница 5: ... Piezo buzzer ensure reliable and accurate operation 125 KHz Proximity PIN Reader ASK Modulation 26 bit Wiegand RS 232 Data Output 4 8 Bit Burst Output Format supported Numeric Keypad with Backlighting for Night Operation Control of External LED Indicators Control of External Buzzer Tamper Switch Reverse Polarity Protection WHAT S INCLUDED Check if the following items are included in the product p...

Страница 6: ... to the power cable 4 6 PIN Connector Can be connected to Wiegand RS 232 communication cables 5 8 PIN Connector Connected to the tamper LED and buzzer control connection cables 6 Output Selection Switch Switch that allows you to select an output from 8 bit 4 bit Burst and Wiegand 7 Tamper Switch Tamper switch 8 Fixing Screw Screws for fixing the devices X Y Z _ lzj lu W zzhTyYWWZ 3 4 7 8 5 6 ...

Страница 7: ...or Tamper Switch NC Tamper NC Green with White Stripes Tamper Switch COM Tamper COM Gray LED Control Red LED Control White with Red Stripes LED Control Green LED Control Yellow LED Control Orange LED Control Blue with White Stripes Buzzer Control BUZZER Control Blue Not Used Not Used Pink Not Used Not Used Sky Blue CABLE SELECTION Item Cable Type 1 Power DC12V Belden 9409 18 AWG 2 Conductor Unshie...

Страница 8: ...he wall mount by inserting the main unit s cables into the center hole and pushing the main unit towards the wall mount Once the main unit is fixed with the wall mount it will not be loosened Please check if the device is operating properly before fixing it If you try to remove the wall mount once it is fixed the lock parts of the wall mount will break resulting in a situation where the whole wall mo...

Страница 9: ...re than one reader side by side or front and back the read range may be reduced In this case if you present a card to one reader the other reader may recognize the same card meaning both readers read the same card simultaneously To avoid this problem keep at least 20 cm of space between the two readers zzhTyYWWZ X Y Z _ lzj lu W Spacer Reader Metal Wall BACK TO BACK INSTALLATION SIDE BY SIDE INSTA...

Страница 10: ...e 12 Buzzer Control Enables you to turn on or off the buzzer To control the buzzer connect the blue line to the controller s output relay see page 12 Tamper Control Connect the COM port gray line of the product s tamper switch to GND connect the NC port green with white stripe of the tamper switch to the input port of the controller RS 232 Connection Connect to the COM port of the PC Connect pin 2...

Страница 11: ...at use the switch on the rear of the product See the table below to make adjustment as needed Output Format SW 1 SW 2 Output Format of Card Output Format of Keypad ON ON 26bit Wiegand RS 232 8bit Burst Default ON OFF 26bit Wiegand RS 232 26bit Wiegand RS 232 OFF ON 26bit Wiegand RS 232 26bit Wiegand RS 232 OFF OFF 26bit Wiegand RS 232 4bit Burst Switch 1 and 2 of SW are set to ON by default Before...

Страница 12: ...n off the indicators according to the I O settings of the controller which can be applied to various situations For more information about the I O settings of the controller refer to the user manual of the controller Connect the yellow line for the green indicator or the blue with white stripes for the orange indicator to the COM port of the controller Buzzer Control Connect the buzzer control inp...

Страница 13: ...ND OUTPUT Timing Diagram Data Type 26 bit Bit 1 Even Parity bit 2 bit 13 Bit 2 9 Facility Code 000 255 Bit 10 25 ID Number 00000 65 535 Bit 26 Odd Parity bit 14 bit 25 100us 1ms DATA 0 DATA 1 1 2 3 5V 0V 0V 5V 0 LOGIC 1 1 1 0 0 n 2 n 1 n n 34 or26 ...

Страница 14: ...ar END 0x03H LRC Check the following settings Baud Rate 9600bps Data Bit 8 Parity Bit None Stop Bit 1 LRC This is the result of XOR operation of each byte from Start to End M Mark 1 Space 0 15V LSB 0 1 1 0 0 0 0 0 0 MSB 3V 3V 15V 0V Data packet corresponding to ASCII character A Start Bit 2 Stop Bits 8 Data Bits Indeterminate Region ...

Страница 15: ...10 6 1 0001 1 7 0111 7 2 0010 2 8 1000 8 3 0011 3 9 1001 9 4 0100 4 ESC 1010 A 5 0101 5 ENT 1011 B 8Bit Burst Output Format Keypads Binary Hexa Keypads Binary Hexa 0 11110000 F0 6 10010110 96 1 11100001 E1 7 10000111 87 2 11010010 D2 8 01111000 78 3 11000011 C3 9 01101001 69 4 10110100 B4 ESC 01011010 5A 5 10100101 A5 ENT 01001011 4B ...

Страница 16: ...t the adaptor should be large enough to cover the current consumption multiplied by the reader count 2 Even with a large adaptor enough to supply adequate power if the power cable is not a dedicated line such as communication line or UPT cable or if it s so long to cause power loss you d better replace it with a dedicated line or reinforce it 3 If the problem persists contact the nearest customer ...

Страница 17: ... these substances can cause harm to human health or the environment To protect natural resources and to promote material reuse please separate batteries from other types of waste and recycle them through your local free battery return system Correct Disposal of This Product Waste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection ...

Страница 18: ...400 TEL 82 70 7147 8740 60 FAX 82 31 8018 3745 SAMSUNG TECHWIN EUROPE LTD Samsung House 1000 Hillswood Drive Hillswood Business Park Chertsey Surrey UNITED KINGDOM KT16 OPS TEL 44 1932 45 5300 FAX 44 1932 45 5325 SAMSUNG TECHWIN AMERICA Inc 1480 Charles Willard St Carson CA 90746 UNITED STATES Tol Free 1 877 213 1222 FAX 1 310 632 2195 www samsungcctvusa com SALES NETWORK ...