4.2. Using Administration Page
27
Note
-
After setting is complete, click the Set button to apply the settings.
4.2.8. Alarm/Sensor
This sets up necessary information when using alarm function by attaching sensor to network server.
For SNS-100 For SNS-400
Alarm/Sensor Setup
◊
Digital In (Sensor) Setup
Item
Description
Sensor Type
Types of sensors are ‘Normal open’ and ‘Normal close.’ This selects up type of connected sensor.
◊
Digital Out (Relay / Alarm) Setup
Item
Description
Relay
Set up Relay Out responding when event is recognized by connected sensor or Motion Detection (MD)
Duration
Set up time to operate relay. It defines the period from the time when sensor detects event to the time when relay
is released.
FTP
In case event occurs by sensor or Motion Detection (MD) on the screen, decide whether transferring related
information to FTP.
In case event occurs by connected sensor or Motion Detection (MD) on the screen, decide whether transferring
related information by e-mail.
FTP / E-mail Setup
Set up FTP server and e-mail information to which related information is transferred in case alarm occurs.
◊
FTP Setup
Item
Description
FTP Server Name
Enters the FTP server or Domain IP address.
Home Directory
Set up home directory to save relevant data at FTP server.
User ID
Enter ID to connect FTP server.
FTP
User Password
Enter PW to connect FTP server.