5
1. Precaution
1- Special High Voltage Precautions
1.
High Voltage Warning Do not attempt to measure any of
the high voltages --this includes the filament voltage of the
magnetron . High voltage is present during any cook cycle .
Before touching any components or wiring, always unplug
the oven and discharge the high voltage capacitor (See
Figure 1-1)
.
The high-voltage capacitor remains charged about 30
seconds after disconnection . Short the negative terminal
of the high-voltage capacitor to to the oven chassis . (Use a
screwdriver .)
3.
High voltage is maintained within specified limits by close-
tolerance, safety-related components and adjustments . If
the high voltage exceeds the specified limits, check each
of the special components .
H . V . Diode
Short
H . V . Capacitor
PRECAUTION
There exists HIGH VOLTAGE ELECTRICITY with high current capabilities in the circuits of the HIGH
VOLTAGE TRANSFORMER secondary and filament terminals. It is extremely dangerous to work on or
near these circuits with the oven energized .
DO NOT measure the voltage in the high voltage circuit including filament voltage of magnetron.
PRECAUTION
Servicemen should remove their watches whenever working close to or replacing the magnetron .
PRECAUTION
Never touch any circuit wiring with your hand nor with uninsulated tool during operation .
Содержание SMH8165B/XAC
Страница 3: ...1 Precaution...