14
Step-by-step installation guide
15
Step-by-step installation guide
C. OUTSIDE BACK EXHAUST (HORIzONTAL DUCT)
5
. Rotate the blower unit counterclockwise 180 °.
6
. Place the blower unit back into the opening.
CAUTION: Do not pull or stretch the blower
unit wiring. make sure the wires are not
pinched.
NOTE: The blower unit exhaust openings
should match exhaust openings on the rear of
microwave oven.
7
. Close the Blower Plate and attach the exhaust
adaptor to the rear of the oven by sliding it into
the guides at the back top center of the oven.
Push in securely until it is in the lower locking
tabs. Take care to ensure that the damper hinge
is installed so that it is at the top and that the
damper swings freely.
B. ATTACH THE mOUNTING
PLATE TO THE WALL
Attach the plate to the wall using toggle bolts. At
least one wood screw must be used to attach the
plate to a wall stud.
1
. Remove the toggle wings from the bolts.
2
. Insert the bolts into the mounting plate through
the holes designated to go into drywall, and
then reattach the toggle wings so that ¾˝ of the
bolt protrudes beyond the wing.
INSTALLATION OVERVIEW
A
. Prepare Rear Wall (horizontal duct only)
B
. Attach Mounting Plate to Wall
C
. Prepare Top Cabinet
D
. Mount the Microwave Oven
E
. Connecting Ductwork (vertical duct only)
A. PREPARING THE REAR
WALL FOR OUTSIDE BACK
EXHAUST
You need to cut an opening in the rear wall for
outside exhaust.
CL
• Read the instructions for outside back exhaust
on the REAR WALL TEMPLATE.
• Tape the REAR WALL TEMPLATE to the rear
wall.
• Cut the opening, following the instructions on
the REAR WALL TEMPLATE.
CAUTION:
Do not cut an opening in the rear wall if
you are installing the microwave with vertical duct or
non-vented ductless ventilation.
3. INSTALLATION
SMH1927_XAA_DE68-04108A-01_EN_120725.indd 15