291
6. Capacity Correction
Outdoor Units
AC052RXADKG/EU
Cooling
Pipe Length (m)
5
10
15
20
25
30
Le
vel Diff
er
enc
e (m
)
30
-
-
-
-
-
-
25
-
-
-
-
-
-
20
-
-
-
0.92 0.90
15
-
-
0.94 0.92 0.90
10
-
0.96 0.94 0.92 0.90
5
0.98 0.96 0.94 0.92 0.90
0
1
0.98 0.96 0.94 0.92 0.90
-5
0.97 0.95 0.93 0.91 0.89
-10
-
0.94 0.93 0.91 0.89
-15
-
-
0.92 0.90 0.88
-20
-
-
-
-
0.89 0.86
-25
-
-
-
-
-
-
-30
-
-
-
-
-
Heating
Pipe Length (m)
5
10
15
20
25
30
Le
vel Diff
er
enc
e (m
)
30
-
-
-
-
-
-
25
-
-
-
-
-
-
20
-
-
-
-
0.94 0.92
15
-
-
-
0.95 0.94 0.92
10
-
-
0.97 0.95 0.94 0.92
5
-
0.98 0.97 0.95 0.94 0.92
0
1
0.98 0.97 0.95 0.94 0.92
-5
-
0.98 0.97 0.95 0.94 0.92
-10
-
-
0.97 0.95 0.94 0.92
-15
-
-
-
0.95 0.94 0.92
-20
-
-
-
-
0.94 0.92
-25
-
-
-
-
-
-
-30
-
-
-
-
-
-