English
_5
Adjusting the response speed
You can adjust the response time by turning the response time control wheel left or right.
Turning it left will speed up the response time; turn it right to slow down the time.
The factory default is set to 250 msec.
Full-speed run – 50 msec
Fast walk – 100 msec
Normal walk – 250 msec
Slow walk – 350 msec
Jump over a fence or obstacle – 500 msec
Installation Instructions
For best performance, you should consider the followings when placing, installing and keeping the product at a distance from
the object.
Do not expose it to a place where its light projector or light receiver is affected by a direct strong light such as sunlight or
headlight. (below ±2 is not allowed in the optical axis)
Do not install it in an unstable, not properly secured place. (wire fence or unsecured pole is not allowed)
Do not install it in a place where the infrared light is blocked due to a seasonal reason such as thick wood or bushes.
Keep it away from the muddy water or sea water keeping splashing. (the infrared light is likely to be blocked by the muddy
water or sea water)
Installation
To mount on the wall
Loosen the screw to remove the cover of the sensor as shown.
Insert the bracket wing on the side as
shown.
If using more than 1 bracket
(max. height 15 cm)
•
•
•
•
•
•
•
•
•
1.
2.
50 msec
500 msec