Samsung Electronics
2-4
Operating Instructions
7. FAN SPEED : Manual (3 step), Auto (4 step)
Fan speed automatically varies depending
on both the difference between setting and
the room temperature.
8. COMPULSORY OPERATION :
For operating the air conditioner without
the remote control.
*The air conditioner starts up in the most
suitable mode for the room temperature:
9. SWING : BLADE-H is rotated vertically by
the stepping motor.
*Swing Set : Press the button under the
remote control is displayed on LCD the
and the blades move up and down. If
the one more time press the button,
blades location is stop.
10. SETTING THE ON/OFF TIMER. :
*ON TIMER : The On Timer enables you
to switch on the air conditioner automati-
cally after a given period of time. You can
set the period of time from 30 minutes to
24 hours.
*OFF TIMER : The Off Timer enables you
to switch off the air conditioner automati-
cally after a given period of time. You can
set the period of time from 30 minutes to
24 hours.
11. GENERATING ANION :
The air conditioner can generate anion
with an ionizer in the indoor unit.
12. SELF DIAGNOSIS
13. BUZZER SOUND : Whenever the On/Off
button is pressed or whenever change
occurs to the condition which is set up or
select, the compulsory operation mode,
buzzer is sounded "beep".
Room Temperature
Less than 21
˚
C
21
˚
C or above
Operating Mode
Heat
Cool
Temperature Setting
22
˚
C approx.
24
˚
C approx.
Indoor unit room temperature sensor
error (open or short)
OFF
E1
OFF
E2
OFF
E3
OFF
E6
All lamp
blinking
All lamp
blinking
Indoor unit heat exchanger temperature
sensor error(open or short)
Indoor FAN MOTOR error :
Keep the RPM value 450 below for 15
seconds
Error in option
In case of No option set-up
In case of option data error
EEPROM error
Error Mode
Operation Off Operation On
DISPLAY 7-SEGMENT
Remark
DB98_13339(A)_1~40 03/5/16 1:59 PM Page 2-4
Содержание SH24TP6
Страница 18: ...MEMO 3 5 Samsung Electronics...
Страница 27: ...Samsung Electronics 5 1 5 Block Diagrams 5 1 Refrigerating Cycle Block Diagram...
Страница 35: ...Samsung Electronics 7 1 Code No DB98 08709A 7 Wiring Diagrams 7 1 Indoor Unit...
Страница 37: ...Wiring Diagrams Samsung Electronics 7 3 DIAGRAM OUTDOOR Code No DB68 02042A UQ24P6GB SH18ZP0 A X UQ T 18...
Страница 38: ...7 4 Samsung Electronics MEMO...
Страница 39: ...Samsung Electronics 8 1 8 Schematic Diagrams 8 1 Indoor Unit 8 1 1 24K 18K BTU AC PART...
Страница 40: ...Schematic Diagrams 8 2 Samsung Electronics 8 1 2 24K 18K BTU DC PART...
Страница 42: ...ELECTRONICS Samsung Electronics Co Ltd May 2003 Printed in Korea Code No DB98 13339A 1...