12-2-14 Compressor start error
1. Checklist :
1) Is the connection of cable for the compressor and power?
2) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Yes
Restart after power off.
Is the restart error occurred again?
Is the interphase resistance value of
compressor (u
↔
v, v
↔
w, w
↔
u) normal?
Is the connection cable for the
compressor and power terminal normal?
Exchange the PCB.
Terminate the service.
Exchange the compressor.
Is the compressor body and
interphase resistance insulated?
Exchange the compressor.
Correct the cable connection.
Yes
Yes
Yes
No
No
No
No
Troubleshooting
12-16
Содержание SH18BW6 Series
Страница 12: ...Samsung Electronics 5 2 Outdoor Unit 5 3...
Страница 15: ...MEMO Samsung Electronics 5 6...
Страница 16: ...Samsung Electronics 5 7 5 4 Ass y Control Out AQV18FAX DB93 04268B AQV24FAX DB93 04268A...
Страница 19: ...8 2 Outdoor Unit This Document can not be used without Samsung s authorization Samsung Electronics 8 2...
Страница 20: ...Samsung Electronics 4 1 4 Disassembly and Reassembly Necessary Tools Item Remark SCREW DRIVER MONKEY SPANNER...
Страница 28: ...MEMO Samsung Electronics 4 9...
Страница 58: ...Samsung Electronics SMPS AC COMMUNICATION SUB PCB INDOOR FAN CONTROL BUZZER CONTROL Block Diagram 13 2...
Страница 60: ...Samsung Electronics OUTDOOR FAN B D IGBT Block Diagram 13 4 DIODE IPM SMPS DC_LINK CAP...
Страница 64: ...This Document can not be used without Samsung s authorization 7 2 Outdoor Unit Samsung Electronics 7 2...
Страница 65: ...7 3 Samsung Electronics MEMO...
Страница 86: ...Samsung Electronics Electrical Parts List MEMO 6 21...
Страница 91: ...Samsung Electronics 11 1 2 Outdoor Unit Operating Instructions 11 2 Air Outlet Air Inlet Rear Connection Valve...